Error messages (continued)
Priority | Monitor display | Description | Corrective action | VTR operation | |
|
|
|
|
|
|
|
|
|
| Check the tape. It is |
|
|
| This appears when the servo is not locked for | possible that a tape | O p e r a t i o n | |
|
| (SERVO NOT | three or more seconds during playback or | recorded by a system | |
|
| LOCKED) | recording. | other than 525/60 has | continues. |
|
| ||||
|
|
|
| been loaded. |
|
|
|
|
|
|
|
|
|
| This appears when an envelope level |
|
|
|
| approximately | Clean the video heads. | O p e r a t i o n | |
|
| (LOW RF) | been detected for more than one second during | continues. | |
|
|
| playback or recording. |
|
|
|
|
|
|
|
|
|
| This appears when the error rate has increased to |
|
| |
|
| the extent that correction or interpolation was |
| O p e r a t i o n | |
|
| (HIGH ERROR | Clean the video heads. | ||
|
| ||||
|
| RATE) | applied to either the video or audio playback |
| continues. |
(Low) | signals. |
|
| ||
|
|
| |||
|
|
|
|
|
|
Error messages
Monitor display | Description | Corrective action | VTR operation | |
|
|
|
| |
| If condensation is detected, the error number flashes and the |
|
| |
| unit transfers to eject mode. The drum rotates after the |
|
| |
| cassette is ejected to eliminate the condensation. |
|
| |
| Once the unit is released from condensation status, the error |
|
| |
message display is cleared and the VTR is able to be used. | Leave the power on and | EJECT | ||
DEW | • If condensation is detected in the eject mode, the drum | wait. | ||
| ||||
| starts rotating as soon as it is detected. |
|
| |
| • If condensation is detected when the cassette has been |
|
| |
| inserted, the drum rotation is stopped, and after the tape |
|
| |
| is ejected, the drum starts rotating. |
|
| |
|
|
|
| |
| The unit switches to eject mode and if the cassette fails to |
|
| |
| move up within 6 seconds, this error number flashes on the |
|
| |
display. | Set the POWER switch |
| ||
FRONT LOAD | Note: | to OFF and then to ON | STOP | |
MOTOR | If the cassette does not move down inside the machine | again. |
| |
| even when 6 seconds have elapsed since the cassette was |
|
| |
| inserted, the VTR is transferred to the eject mode. |
|
| |
|
|
|
| |
| If the unloading operation is not completed within 6 |
|
| |
seconds, this error number flashes on the display. | Set the POWER switch |
| ||
Note: |
| |||
LOADING | to OFF and then to ON | STOP | ||
When the loading operation is not completed within 6 | ||||
MOTOR | again. |
| ||
| seconds, the VTR is transferred to the eject (unloading) |
|
| |
| mode. |
|
| |
|
|
|
| |
If there is no response from the servo microcomputer for 1 | Set the POWER switch |
| ||
SERVO CONTROL | to OFF and then to ON | STOP | ||
ERROR | second or more, this error number flashes on the display. | again. |
| |
|
| |||
|
|
|
| |
If 10 seconds or more elapses and the servo | Set the POWER switch |
| ||
SERVO COMM | microcomputer has not followed orders issued by the | to OFF and then to ON | STOP | |
ERROR | system control microcomputer, this error number flashes on | again. |
| |
| the display. |
|
| |
|
|
|
| |
If the | Set the POWER switch |
| ||
FRONT LOAD | period of time during the start or end processing operation | to OFF and then to ON | STOP | |
ERROR | while loading is underway (half position), this error number | again. |
| |
| flashes on the display. |
|
| |
|
|
|
| |
If the | Set the POWER switch |
| ||
traveling in the state where the total amount of the tape has | to OFF and then to ON | STOP | ||
NOT ROTA | not yet been detected after the cassette was inserted, this | again. |
| |
| error number flashes on the display. |
|
| |
|
|
|
|
41