Error messages (continued)
Monitor display | Description | Corrective action | VTR operation | |
|
|
|
| |
| If there is an abnormally large discrepancy between the |
|
| |
amount of tape taken up by the | Set the POWER switch |
| ||
amount of tape supplied by the supply reel while the tape is | to OFF and then to ON | STOP | ||
WINDUP ERROR | ||||
traveling after the total amount of the tape begins to be | again. |
| ||
|
| |||
| detected, this error number flashes on the display. |
|
| |
|
|
|
| |
If the tape has not been taken up during unloading, this | Set the POWER switch to | STOP | ||
UNLOAD ERROR | error number flashes on the display. | OFF and then to ON again. | ||
| ||||
|
|
|
| |
If the start or end processing operation is not completed, | Set the POWER switch |
| ||
to OFF and then to ON | STOP | |||
TIMEOVER | this error number flashes on the display. | again. |
| |
|
| |||
|
|
|
| |
If the cylinder motor speed is abnormally low, this error | Set the POWER switch |
| ||
DRUM ROTA | to OFF and then to ON | STOP | ||
TOO SLOW | number flashes on the display. | again. |
| |
|
| |||
|
|
|
| |
If the cylinder motor speed is abnormally high, this error | Set the POWER switch |
| ||
DRUM ROTA | to OFF and then to ON | STOP | ||
TOO FAST | number flashes on the display. | again. |
| |
|
| |||
|
|
|
| |
If the capstan motor speed is abnormally low, the error | Set the POWER switch |
| ||
CAP ROTA | to OFF and then to ON | STOP | ||
TOO SLOW | number flashes on the display. | again. |
| |
|
| |||
|
|
|
| |
If the supply reel motor speed is abnormally high, the error | Set the POWER switch |
| ||
S REEL ROTA | to OFF and then to ON | STOP | ||
TOO FAST | number flashes on the display. | again. |
| |
|
| |||
|
|
|
| |
If the | Set the POWER switch |
| ||
T REEL ROTA | to OFF and then to ON | STOP | ||
TOO FAST | number flashes on the display. | again. |
| |
|
| |||
|
|
|
| |
If excess torque being applied to the | Set the POWER switch |
| ||
T REEL | to OFF and then to ON | STOP | ||
TORQUE ERR | detected, the error number flashes on the display. | again. |
| |
|
| |||
|
|
|
| |
If excess torque being applied to the supply reel motor is | Set the POWER switch |
| ||
S REEL | detected or an abnormal current flowing to the current | to OFF and then to ON | STOP | |
TORQUE ERR | detection resistor is detected, this error number flashes on | again. |
| |
| the display. |
|
| |
If abnormal tension at the supply side is detected in the | Set the POWER switch |
| ||
CAP TENSION | to OFF and then to ON | STOP | ||
ERROR | capstan mode, the error number flashes on the display. | again. |
| |
|
| |||
|
|
|
| |
If abnormal tension at the supply side is detected in the reel | Set the POWER switch |
| ||
REEL TENSION | to OFF and then to ON | STOP | ||
ERROR | mode, the error number flashes on the display. | again. |
| |
|
| |||
|
|
|
| |
If the | Set the POWER switch |
| ||
REEL DIR | to OFF and then to ON | STOP | ||
UNMATCH | direction, this error number flashes on the display. | again. |
| |
|
| |||
|
|
|
| |
If excess torque being applied to the cylinder motor is | Set the POWER switch |
| ||
DRUM TORQUE | to OFF and then to ON | STOP | ||
ERROR | detected, this error number flashes on the display. | again. |
| |
|
| |||
|
|
|
| |
If a problem has been encountered in communication | Set the POWER switch |
| ||
between the servo microcomputer and mechanism relay | to OFF and then to ON | STOP | ||
ERROR | board, this error number flashes on the display. | again. |
| |
|
|
|
|
Note:
Consult your dealer if the error message is still displayed even after restarting the unit.