Error messages (continued)

Monitor display

Description

Corrective action

VTR operation

 

 

 

 

 

If there is an abnormally large discrepancy between the

 

 

E-53

amount of tape taken up by the take-up reel and the

Set the POWER switch

 

amount of tape supplied by the supply reel while the tape is

to OFF and then to ON

STOP

WINDUP ERROR

traveling after the total amount of the tape begins to be

again.

 

 

 

 

detected, this error number flashes on the display.

 

 

 

 

 

 

E-55

If the tape has not been taken up during unloading, this

Set the POWER switch to

STOP

UNLOAD ERROR

error number flashes on the display.

OFF and then to ON again.

 

 

 

 

 

E-57

If the start or end processing operation is not completed,

Set the POWER switch

 

S-FF/REW

to OFF and then to ON

STOP

TIMEOVER

this error number flashes on the display.

again.

 

 

 

 

 

 

 

E-59

If the cylinder motor speed is abnormally low, this error

Set the POWER switch

 

DRUM ROTA

to OFF and then to ON

STOP

TOO SLOW

number flashes on the display.

again.

 

 

 

 

 

 

 

E-60

If the cylinder motor speed is abnormally high, this error

Set the POWER switch

 

DRUM ROTA

to OFF and then to ON

STOP

TOO FAST

number flashes on the display.

again.

 

 

 

 

 

 

 

E-61

If the capstan motor speed is abnormally low, the error

Set the POWER switch

 

CAP ROTA

to OFF and then to ON

STOP

TOO SLOW

number flashes on the display.

again.

 

 

 

 

 

 

 

E-64

If the supply reel motor speed is abnormally high, the error

Set the POWER switch

 

S REEL ROTA

to OFF and then to ON

STOP

TOO FAST

number flashes on the display.

again.

 

 

 

 

 

 

 

E-67

If the take-up reel motor speed is abnormally high, the error

Set the POWER switch

 

T REEL ROTA

to OFF and then to ON

STOP

TOO FAST

number flashes on the display.

again.

 

 

 

 

 

 

 

E-69

If excess torque being applied to the take-up reel motor is

Set the POWER switch

 

T REEL

to OFF and then to ON

STOP

TORQUE ERR

detected, the error number flashes on the display.

again.

 

 

 

 

 

 

 

E-70

If excess torque being applied to the supply reel motor is

Set the POWER switch

 

S REEL

detected or an abnormal current flowing to the current

to OFF and then to ON

STOP

TORQUE ERR

detection resistor is detected, this error number flashes on

again.

 

 

the display.

 

 

E-71

If abnormal tension at the supply side is detected in the

Set the POWER switch

 

CAP TENSION

to OFF and then to ON

STOP

ERROR

capstan mode, the error number flashes on the display.

again.

 

 

 

 

 

 

 

E-72

If abnormal tension at the supply side is detected in the reel

Set the POWER switch

 

REEL TENSION

to OFF and then to ON

STOP

ERROR

mode, the error number flashes on the display.

again.

 

 

 

 

 

 

 

E-73

If the take-up reel motor has rotated in the reverse

Set the POWER switch

 

REEL DIR

to OFF and then to ON

STOP

UNMATCH

direction, this error number flashes on the display.

again.

 

 

 

 

 

 

 

E-74

If excess torque being applied to the cylinder motor is

Set the POWER switch

 

DRUM TORQUE

to OFF and then to ON

STOP

ERROR

detected, this error number flashes on the display.

again.

 

 

 

 

 

 

 

E-78

If a problem has been encountered in communication

Set the POWER switch

 

M-IF COMM

between the servo microcomputer and mechanism relay

to OFF and then to ON

STOP

ERROR

board, this error number flashes on the display.

again.

 

 

 

 

 

Note:

Consult your dealer if the error message is still displayed even after restarting the unit.

42