Parts and their functions
Front panelPOWER |
|
|
|
|
|
|
|
|
|
| EJECT |
ON |
|
|
|
|
|
|
|
|
|
|
|
OFF |
|
|
|
|
|
|
|
|
|
|
|
CONTROL | REC INHIBIT |
|
|
|
|
|
|
|
|
| |
LOCAL REMOTE | OFF | ON |
| Digital Video Cassette Recorder AJ- |
|
|
|
| |||
METER |
|
|
|
|
|
|
|
|
|
| PUSH |
FULL/FINE |
|
|
|
|
|
|
|
|
|
| SHTL/SLOW |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| SEARCH | PLAY | REC | |
|
|
|
|
|
|
|
|
|
| ||
MONITOR SEL |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| REW | STOP | FF |
HEADPHONES | CH 1 | CH 2 | CH 1 | CH 2 | UNITY | VAR | INPUT SELECT | COUNTER RESET | TC | INT | TCG SUPER |
|
|
|
|
| VIDEO AUDIO | PRESET | MENU | ON | |||
|
|
|
|
|
|
|
|
| REGEN | ||
|
|
|
|
|
|
|
|
|
| PRESET | OFF |
|
| REC |
| PB |
|
|
|
|
| EXT | |
|
|
|
|
| PF | PF1 PF2 | PF3 | DIAG |
|
POWER switch
Cassette insertion slot
EJECT button
When this button is pressed, the tape is unloaded and the cassette is ejected automatically a few seconds later. When CTL display has been selected for the counter display, the display is reset.
EJECT button operation can be enabled or disabled with setup menu No. 115 (EJECT SW INH).
CONTROL switch
This is selected to control the unit from an external source using the REMOTE connector.
REMOTE: Set to this position to control the unit using the
LOCAL : Set to this position to control the unit using the controls on the unit's operation panel.
REC INHIBIT switch
This switch is used to enable or disable recording on the cassette tape.
ON:
Recording on the cassette tape is disabled (inhibited).
In this state, the REC INH lamp lights on the display panel.
OFF:
Recording on the cassette tape is enabled so long as the accidental erasure prevention mechanism on the cassette tape is set to enable recording.
METER (FULL/FINE) selector button
This button is used to select the scale display for the
audio level meter. |
|
| |
FULL mode | : The standard scale (– ∞ to 0 dB) is | ||
| selected. |
|
|
FINE mode | : The scale in 0.5 dB increments is | ||
| selected. The |
| position indicates the |
|
| ||
| standard level of | ||
| page 11) |
|
|
MONITOR SEL button
This button is used to select the audio signals which are to be output to the AUDIO MON L and R connectors. Each time the button is pressed, the audio signals to be output to the AUDIO MON L or R connector are changed in the following sequence.
L: [CH1] → [CH1] →[CH2] → [CH1+CH2] R : [CH2] [CH1] [CH2] [CH1+CH2]
Which signal is currently selected is displayed by the lighting of the L or R lamp on the level meter display.
Headphone jack and volume control
When stereo headphones are connected to the headphone jack, the sound can be monitored using the headphones during recording or playback.
Audio level control knobs
These knobs are used to adjust the recording and playback level of the PCM audio signals (CH1 and CH2).
The audio level control selector switch is used to set to variable or fixed level.
Note:
The level of the IEEE1394 digital input/output audio signals cannot be adjusted.
Audio level control selector switch
UNITY: At this position, the audio signals are recorded or played back at a fixed level regardless of the position of the audio level control knobs .
VAR: At this position, the audio signals are recorded or played back at the level adjusted by the audio level control knobs .
Note:
When UNITY is selected, the recording and playback levels both become UNITY (fixed level).
8