Major operating controls and their functions

HD SDI output connector [HD SDI OUT]

SDI signal output is given by this line.

G/L input connector [G/L IN]

For gen-lock with the camera, the external sync signal (black burst) or tri-level sync signal is supplied to this input connector.

Cable clamp

Clamp the DC power supply cable connected to the DC 12 V input connector to prevent it from slipping out.

Optional card slot

Slot for inserting an optional card. For details, refer to the manual for optional cards.

Cooling fan

Do not block or obstruct the ventilation during operation. It may otherwise cause internal heating or fire.

The life of this fan is approximately 50,000 hours (at room temp. 77°F (25°C)). Replace the fan as needed.

(When the room temperature is higher than 95°F (35°C), replace the fan 30% earlier.) Be sure to ask the dealer for the replacement.

Interface connector [I/F]

5

10

15

Pin No.

Signal

 

 

1

Gen-lock signal GND

 

 

 

 

 

 

2

Time code signal input

1

 

11

3

Not used

6

4

TX_N (EIA422)/TXD (EIA232) output

 

 

 

 

 

 

5

RX_N (EIA422)/RXD (EIA232) output

 

 

 

6

Camera power supply input (DC +12 V)

 

 

 

7

Gen-lock signal input

 

 

 

8

GND

 

 

 

9

TX_P (EIA422) output

 

 

 

10

RX_P (EIA422) input

 

 

 

11

GND

 

 

 

12

Time code signal GND

 

 

 

13

GND

 

 

 

14

GND

 

 

 

15

GND

ENGLISH

- 10 (E) -

Page 11
Image 11
Panasonic AK-HC1500G operating instructions  HD SDI output connector HD SDI OUT