2. Basic operations
RECALL: This is used to recall the preset memory data and change the panel settings.
1Press the [FUNC] switch to light its indicator, and then press the [MEM] switch to display the PSMEM (1/3) menu.
2Turn [F2], select “RECL” using the MODE item, turn [F3], and set the preset memory number using the NO. item.
3Press the [F4] switch (EXEC) to recall the settings.
If the asterisk () is not displayed at the left of the preset memory number, the panel status will remain unchanged even when the settings in the preset memory are recalled.
Recall settings can be selected for the crosspoint settings. ENBL: The data stored in the preset memory is used.
DSBL: The data stored in the preset memory is not used, and the settings prior to recall are retained.
1Press the [FUNC] switch to light its indicator, and then press the [MEM] switch to display the PSMEM (1/3) menu.
2Turn [F1] to display the PSMEM (2/3) menu.
3Turn [F2], and select crosspoint disable (DSBL) or enable (ENBL) using the XPT item.
14.&. 915 %4#-
&/#-
CLEAR: This is used to clear contents in the preset memory.
1Press the [FUNC] switch to light its indicator, and then press the [MEM] switch to display the PSMEM (1/3) menu.
2Turn [F2], select “CLR” using the MODE item, turn [F3], and set the preset memory number using the NO. item.
3Press the [F4] switch (EXEC) to clear the content.
When the memory settings are cleared, the asterisk () at the left of the preset memory number will not be displayed.
27