Panasonic AW-PH405N Cable specifications, When connecting a Fujinon extender change unit, Shell

Models: AW-PH405N

1 32
Download 32 pages 51.85 Kb
Page 26
Image 26
Cable specifications

Cable specifications

When connecting a Canon lens with motorized extender unit

Connector: HR10A-10P-10P (73) made by Hirose Electric

CVCC (12 V)

CGND

EXT Return

EXT Signal

ND Return

ND Signal

CanonEXT ()

CanonEXT ()

GND

GND

SHELL

Connect this connector to the ND/EXT connector on the pan-tilt head

Connector: HR10A-7P-6S (73) made by Hirose Electric

SHELL

Connect this connector to the EXT connector on the lens

When connecting a Fujinon extender change unit

Connector: HR10A-10P-10P (73) made by Hirose Electric

CVCC (12 V)

CGND

EXT Return

EXT Signal

ND Return

ND Signal

CanonEXT ()

CanonEXT ()

GND

GND

SHELL

Connect this connector to the ND/EXT connector on the pan-tilt head

Connector: HR10A-7P-5P (73) made by Hirose Electric

SHELL

Connect this connector to the 5-pin connector on the extender change unit

For details on how to connect the extender change unit to the lens, consult the information provided by the manufacturer of the lens.