RACK MOUNTING

RACK MOUNTING

Do not mount the Live Switcher on a closed rack or bookshelf. (Otherwise, heat will build up inside and may cause a fire.)

Keep the ventilation port open to secure good flow of air.

 

 

 

POWER

 

 

 

 

 

 

 

 

 

COM

WIPE

PATTERN

 

 

 

 

 

 

 

IN

 

 

 

 

 

 

 

GEN-

LEVEL

 

 

 

 

 

TRAN

 

 

 

LOCK

PHASE

 

 

 

 

 

SITION

 

 

 

 

 

 

 

 

 

 

TIME

 

2

 

 

 

GAIN

K

EY

 

 

 

Rack mounting parts

1

A

 

 

 

 

CLIP

 

 

A

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

Connecting

plateMounting screw

Mounting screw

Holes for connecting plate (Bottom)

INFORMATION RELATED TO SYSTEM UPGRADES

(1)Switcher phases

1)Video signal output phase (frame synchronizer is OFF)

Video signal input phase

Video signal output phase

 

Approx. 50nS

 

BB phase

2) Video signal input phase (frame synchronizer is ON)

Input phase range

max. of 1 frame

BB phase

3) Genlock adjustment range

 

 

Approx.

Approx. 3µS

 

1µS

 

 

 

BB phase

(2) TALLY & INCOM connectors

Use a Mini DIN type 6-pin connector for tally and intercom connections. (e.g.) TCP8060-01-520 manufactured by Hosiden Corporation