REMOTE Specifications

This monitor permits remote operation from an external.

GPI terminal

GPI screen items correspond to the following terminals.

The functions assigned to each terminal operate when GND (pin 5) is short-circuited (ON) or open (OFF).

 

Pin

Signal

 

 

 

 

1

GPI1

 

2

GPI2

GPI terminals (9P)

3

GPI3

 

4

GPI4

 

5

GND

 

6

GPI5

 

7

GPI6

 

8

GPI7

 

 

 

 

9

GPI8

 

 

 

Operating conditions

Level operation: Operates when GND is short-

circuited.

Edge operation: Operates when GND changes from open to short-circuited.

Edge operation should be maintained for approximately 0.2 s or more after a change.

Terminal

Assigned item

Function

Operating conditions

 

 

 

 

GPI1

INPUT SEL. VIDEO

Switches the input line to VIDEO.

Edge operation

 

 

 

 

GPI2

INPUT SEL. SDI1

Switches the input line to SDI1.

Edge operation

 

 

 

 

GPI3

INPUT SEL. SDI2

Switches the input line to SDI2.

Edge operation

 

 

 

 

GPI4

INPUT SEL. HDMI

Switches the input line to HDMI.

Edge operation

 

 

 

 

GPI5

INPUT SEL. YPBPR

Switches the input line to YPBPR.

Edge operation

 

 

 

 

GPI6

INPUT SEL. PC

Switches the input line to PC.

Edge operation

 

 

 

 

GPI7

R-TALLY*1

Lights the red tally lamp.

Level operation

 

 

 

(Short-circuited: ON, Open: OFF)

 

 

 

 

GPI8

G-TALLY*1

Lights the green tally lamp.

Level operation

 

 

 

(Short-circuited: ON, Open: OFF)

 

 

 

 

*1 When R-TALLY and G-TALLY simultaneously go on, the tally lamp's color changes to amber.