Panasonic CS/CU-A12CTP5 Preparation Before Operation, How To Operate, Remote Control, Indoor Unit

Models: CS/CU-A12CTP5

1 4
Download 4 pages 40.95 Kb
Page 2
Image 2
■Remote Control

CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5

NAME OF EACH PART

How to Insert the Batteries

Remote Control

PREPARATION BEFORE OPERATION H ■ Indoor UnitHOW TO OPERATEManual backgroundManual backgroundH

1 Signal Transmitter

2 Operation Display

Cooling Model

1 Gently press the place marked OPEN and slide the cover towards you.

 

2

Insert the batteries

 

 

– Be sure the direction is correct.

Heat Pump Model

About the batteries

 

 

• Can be used for approximately one year.

 

Observe the following when replacing the batteries

 

 

• Replace with new batteries of the same type.

 

 

• Do not use rechargeable batteries (Ni-Cd).

 

 

• Remove the batteries if the unit is not going to be

 

 

used for a long period.

Remote Control Signal.

Make sure it is not obstructed.

Maximum distance : 10 m.

Signal received sound.

One short beep or one long beep.

Notes for Remote Control.

Do not throw or drop.

Do not get it wet.

Certain type of fluorescent lamps may affect signal reception. Consult your dealer.

Do not place the remote control in a location exposed to direct sunlight, or next to a heating unit, or other heat source.

3 Room Temperature Setting Button (Illuminating button)

4 Operation Mode Selection Button

5 Sleep Mode Operation Button (Illuminating button)

6 Timer Setting Button

7 Timer Selection Button

8 OFF/ON Button (Illuminating button)

9 Fan Speed Selection Button

0 Auto Airflow Direction Button

!Timer Set/Cancel Button

@Manual Airflow Direction Selection Button

#Reset Point

(Press with fine-tipped object to clear the memory)

Proper way to operate the remote control in the case of ceiling/wall mounting.

Operate the remote control in parallel with the floor. (See the figure below)

(Fig. 1) Horizontal Level

O.K.

The signal changes as shown in the figure below. It means that the receiving conditions are bad and the signal can not be controlled properly.

(Fig. 2)

OUT

PREPARATION BEFORE OPERATION

Indoor Unit

1

1Connect the power supply cord to an independent power supply.

HOW TO OPERATE

To start the operation

Press 1.

POWER indicator (green) on the indoor unit will light up.

To stop, press once more.

Setting Mode

Press 2 to select:-

Cooling Model

AUTO – Automatic Operation

COOL – Cooling Operation

DRY – Soft Dry Operation

FAN – Air Circulation Operation

Heat Pump Model

AUTO – Automatic Operation

HEAT – Heating Operation

COOL – Cooling Operation

DRY – Soft Dry Operation

Setting Temperature

Press 3 to increase or decrease the temperature.

The temperature can be set between 16°C ~ 30°C

Recommended temperature:

 

Cooling Model

 

 

 

Heat Pump Model

 

 

 

 

 

 

COOL –> 26°C ~ 28°C

 

 

 

 

COOL –> 26°C ~ 28°C

 

 

 

DRY –> 1°C ~ 2°C

 

 

 

DRY

–> 1°C ~ 2°C

 

 

lower than the

 

 

 

 

lower than the

 

 

 

 

 

 

room temperature

 

 

 

 

room temperature

 

 

 

 

 

 

 

 

HEAT

–> 20°C ~ 24°C

 

During AUTO Operation, press 3 to select:-

• Operation with 2°C higher than the standard temperature.

• Operation with the standard temperature.

• Operation with 2°C lower than the standard temperature.

Standard Temperature

Cooling Model

Indoor

Operation

Standard

temperature

temperature

 

Cooling

25°C

23°C

Soft Dry

22°C

Once the Automatic Operation is selected, the indoor temperature sensor operates automatically to select the desired operation mode with Cooling or Soft Dry.

After the operation mode has been selected, the mode does not change.

Heat Pump Model

Indoor

Operation

Standard

temperature

temperature

 

Cooling

25°C

23°C

Soft Dry

22°C

20°C

Heating

21°C

At the beginning of the automatic operation, Heating, Cooling or Soft Dry is automatically selected according to the indoor temperature.

After the operation mode has been selected, the mode does not change.

Operation Details

COOL – Cooling Operation

To set the room temperature at your preference cooling comfort.

AUTO – Automatic Operation

Sense indoor temperature to select the optimum mode.

Temperature is not displayed on the remote control during AUTO operation.

DRY – Soft Dry Operation

A very gentle Cooling Operation, prior to dehumidification. It does not lower the room temperature.

During Soft Dry operation, the indoor fan operates at Low Fan Speed.

HEAT – Heating Operation (for Heat Pump Model only)

Heat is obtained from outdoor air to warm up the room. When the outdoor ambient air temperature falls, the heating capacity of the unit might be reduced.

Defrosting Operation

Depend on the outdoor temperature, the operation occasionally stops to melt the frost on the outdoor unit.

FAN – Air Circulation Operation

(for Cooling Model only)

Heated air rises and collects at the top of the room. The air circulation circulates the heated air downward, thus increasing heating effectiveness. When the unit is installed floor mounted, you should set the temperature higher than that of ceiling mounted.

At ceiling mounted

At floor mounted

36