NAME OF EACH PART
● How to Insert the Batteries
■Remote Control
H H
1 Signal Transmitter |
2 Operation Display |
Cooling Model |
1 Gently press the place marked OPEN and slide the cover towards you.
| 2 | Insert the batteries |
|
| – Be sure the direction is correct. |
Heat Pump Model | ● About the batteries | |
|
| • Can be used for approximately one year. |
| ● Observe the following when replacing the batteries | |
|
| • Replace with new batteries of the same type. |
|
| • Do not use rechargeable batteries |
|
| • Remove the batteries if the unit is not going to be |
|
| used for a long period. |
●Remote Control Signal.
•Make sure it is not obstructed.
•Maximum distance : 10 m.
•Signal received sound.
One short beep or one long beep.
●Notes for Remote Control.
•Do not throw or drop.
•Do not get it wet.
•Certain type of fluorescent lamps may affect signal reception. Consult your dealer.
●Do not place the remote control in a location exposed to direct sunlight, or next to a heating unit, or other heat source.
3 Room Temperature Setting Button (Illuminating button)
4 Operation Mode Selection Button
5 Sleep Mode Operation Button (Illuminating button)
6 Timer Setting Button
7 Timer Selection Button
8 OFF/ON Button (Illuminating button)
9 Fan Speed Selection Button
0 Auto Airflow Direction Button
!Timer Set/Cancel Button
@Manual Airflow Direction Selection Button
#Reset Point
(Press with
●Proper way to operate the remote control in the case of ceiling/wall mounting.
•Operate the remote control in parallel with the floor. (See the figure below)
(Fig. 1) Horizontal Level | O.K. |
•The signal changes as shown in the figure below. It means that the receiving conditions are bad and the signal can not be controlled properly.
(Fig. 2) | OUT |
PREPARATION BEFORE OPERATION
■ Indoor Unit
1
1Connect the power supply cord to an independent power supply.
HOW TO OPERATE
■To start the operation
•Press 1.
•POWER indicator (green) on the indoor unit will light up.
•To stop, press once more.
■Setting Mode
•Press 2 to select:-
Cooling Model
AUTO – Automatic Operation
COOL – Cooling Operation
DRY – Soft Dry Operation
FAN – Air Circulation Operation
Heat Pump Model
AUTO – Automatic Operation
HEAT – Heating Operation
COOL – Cooling Operation
DRY – Soft Dry Operation
■Setting Temperature
•Press 3 to increase or decrease the temperature.
•The temperature can be set between 16°C ~ 30°C
•Recommended temperature:
| Cooling Model |
|
|
| Heat Pump Model |
| |||
|
|
|
| ||||||
| COOL |
|
|
|
| COOL |
|
| |
| DRY |
|
|
| DRY |
| |||
| lower than the |
|
|
|
| lower than the |
| ||
|
|
|
| ||||||
| room temperature |
|
|
|
| room temperature |
|
| |
|
|
|
|
|
| HEAT |
|
•During AUTO Operation, press 3 to select:-
• Operation with 2°C higher than the standard temperature.
• Operation with the standard temperature.
• Operation with 2°C lower than the standard temperature.
●Standard Temperature
Cooling Model
Indoor | Operation | Standard |
temperature | temperature | |
| Cooling | 25°C |
23°C | Soft Dry | 22°C |
•Once the Automatic Operation is selected, the indoor temperature sensor operates automatically to select the desired operation mode with Cooling or Soft Dry.
•After the operation mode has been selected, the mode does not change.
Heat Pump Model
Indoor | Operation | Standard |
temperature | temperature | |
| Cooling | 25°C |
23°C | Soft Dry | 22°C |
20°C | Heating | 21°C |
•At the beginning of the automatic operation, Heating, Cooling or Soft Dry is automatically selected according to the indoor temperature.
•After the operation mode has been selected, the mode does not change.
●Operation Details
COOL – Cooling Operation
•To set the room temperature at your preference cooling comfort.
AUTO – Automatic Operation
•Sense indoor temperature to select the optimum mode.
•Temperature is not displayed on the remote control during AUTO operation.
DRY – Soft Dry Operation
•A very gentle Cooling Operation, prior to dehumidification. It does not lower the room temperature.
•During Soft Dry operation, the indoor fan operates at Low Fan Speed.
HEAT – Heating Operation (for Heat Pump Model only)
•Heat is obtained from outdoor air to warm up the room. When the outdoor ambient air temperature falls, the heating capacity of the unit might be reduced.
•Defrosting Operation
Depend on the outdoor temperature, the operation occasionally stops to melt the frost on the outdoor unit.
FAN – Air Circulation Operation
(for Cooling Model only)
•Heated air rises and collects at the top of the room. The air circulation circulates the heated air downward, thus increasing heating effectiveness. When the unit is installed floor mounted, you should set the temperature higher than that of ceiling mounted.
At ceiling mounted | At floor mounted |
36