Panasonic CS-KS12NB41, CS-KS18NB4UW How to Disconnect, How to Connect, Pull the cover upward

Models: CZ-18BT1U + CU-KS18NKU CZ-18BT1U + CU-KS12NK1A CZ-18BT1U + CU-KS18NKUA CS-KS18NB4UW CS-KS12NB41

1 69
Download 69 pages 12.68 Kb
Page 40
Image 40
Pull the cover upward

7-2. Disconnecting and Connecting Positive Connector for Outdoor Unit

Pull the cover upward

When the cover is pulled upward, the lock is released with the sequence of 1 and 2.

One of the two types of connectors illustrated at left is used. Their basic structure is the same for each.

How to Disconnect

Hold the resin connector cover, and pull the connector off. You cannot disconnect the connector by pulling the wire since it is locked inside. Always hold the cover to disconnect. (See illustration at left.) For the connector without the resin cover, push the lock in the direction of "2" while pulling it off.

How to Connect

In order to connect, hold the resin cover of the connector and push it in. Confirm the click sound for the inside lock.

40

Page 40
Image 40
Panasonic CS-KS12NB41, CS-KS18NB4UW, CZ-18BT1U + CU-KS18NKUA How to Disconnect, How to Connect, Pull the cover upward