Panasonic CS-KS18NB4UW, CS-KS12NB41 service manual Checking Continuity of Fuse on PCB Assy

Models: CZ-18BT1U + CU-KS18NKU CZ-18BT1U + CU-KS12NK1A CZ-18BT1U + CU-KS18NKUA CS-KS18NB4UW CS-KS12NB41

1 69
Download 69 pages 12.68 Kb
Page 61
Image 61
10-2. Checking Continuity of Fuse on PCB Ass'y

10-2. Checking Continuity of Fuse on PCB Ass'y

Manual background Remove the PCB Ass'y from the electrical component box. Then pull out the fuse from the PCB Ass'y. (Fig. 5)

Manual background Check for continuity using a multimeter as shown in Fig. 6.

Fuse

PCB Ass'y

Fig. 5

Fuse

Fig. 6

61

Page 61
Image 61