PREPARATION BEFORE OPERATION

Indoor Unit

HOW TO OPERATE

Setting Temperature

Press 3 to increase or decrease the temperature.

The temperature can be set between 60°F ~ 86°F.

Recommended temperature:

1

 

 

 

A

 

 

 

 

UT

 

 

 

 

OH

 

 

 

 

EAT

 

2

 

ON

C

OOL

O

A

 

FF

 

UT

 

 

 

 

O

DRY FAN

Cooling Model

COOL –> 75°F ~ 78°F

Heat Pump Model

COOL –> 75°F ~ 78°F

5

 

2

3

4

3

5

O

FF

C

HE

CK

AUTO

O

1

N

 

TIMER

 

 

 

QUIET

TEMP

A

UT

 

 

 

FA

 

 

 

N

O

 

 

 

 

 

 

MODE

 

 

 

 

 

 

O

 

 

 

 

AIR

 

 

E

 

 

 

 

F

F

 

 

 

 

C

 

 

 

 

 

 

 

 

SWING

 

O

 

 

 

 

/O

 

 

 

 

 

N

 

 

 

 

 

 

 

 

 

O

 

 

N

 

 

 

 

 

 

 

M

 

 

 

 

 

 

 

 

 

 

Y

 

 

 

 

 

MANUAL

 

 

 

 

P

 

 

 

 

 

 

 

 

 

O

 

 

 

 

 

 

 

 

 

WE

 

 

 

 

 

 

 

 

 

RF

 

 

 

 

2

 

 

 

FAN

UL

 

 

 

 

 

 

 

 

 

SPEED

 

 

 

 

 

 

SET

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

6

4

DRY –> 2°F ~ 4°F lower than the room temperature

DRY –> 2°F ~ 4°F lower than the

room temperature

HEAT –> 68°F ~ 75°F

1

Open the front panel

2

 

R

 

ES

 

ET

C

 

LO

 

CK

CANCEL

During AUTO Operation, press 3 to select:-

 

Remove the air filters

3

Fit the air purifying filters in place

4

Insert the air filters

5

Close the front panel

Remote Control – To set the current time

AIR SWING

AUTO MANUAL FAN SPEED

1

2

3

ON

 

SET

OFF

 

CANCEL

 

TIMER

2

 

 

1

CHECK RESET CLOCK

1Press 1.

2Then press 2 to increase or decrease the time.

3Press 1 again.

Set time on display will light up.

To start the operation

Press 1.

POWER indicator (green) on the indoor unit will light up.

To stop, press once more.

Setting Mode

Press 2 to select:-

Cooling Model

AUTO – Automatic Operation

COOL – Cooling Operation

DRY – Soft Dry Operation

FAN – Air Circulation Operation

Heat Pump Model

AUTO – Automatic Operation

HEAT – Heating Operation

COOL – Cooling Operation

DRY – Soft Dry Operation

• Operation with 4°F higher than the standard temperature.

• Operation with the standard temperature.

• Operation with 4°F lower than the standard temperature.

Standard Temperature

Cooling Model

Indoor

Operation

Standard

temperature

temperature

 

Cooling

77°F

73°F

Soft Dry

72°F

Once the Automatic Operation is selected, the indoor temperature sensor operates automatically to select the desired operation mode with Cooling or Soft Dry.

After the operation mode has been selected, the mode does not change.

Heat Pump Model

Indoor

Operation

Standard

temperature

temperature

 

Cooling

77°F

73°F

Soft Dry

72°F

68°F

Heating

70°F

At the beginning of the automatic operation, Heating, Cooling or Soft Dry is automatically selected according to the indoor temperature.

The operation mode changes every hour, when necessary.

5