Panasonic CU-CE12GKE Sensible Capacity Chart, OCS-CE7GKEW CU-CE7GKE, OCS-CE9GKEW CU-CE9GKE

Models: CS-CE9GKEW CS-CE12GKEW CS-CE7GKEW CU-CE7GKE CU-CE12GKE CU-CE9GKE

1 24
Download 24 pages 48.93 Kb
Page 20
Image 20

2.2.Sensible Capacity Chart

OCS-CE7GKEW CU-CE7GKE

230V

 

 

 

 

 

Outdoor Temp. (°C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor wet

 

30

 

 

35

 

 

40

 

 

46

 

bulb temp.

TC

SHC

IP

TC

SHC

IP

TC

SHC

IP

TC

SHC

IP

 

 

 

 

 

 

 

 

 

 

 

 

 

17.0°C

2.03

1.54

0.44

1.90

1.48

0.47

1.77

1.42

0.51

1.61

1.35

0.55

 

 

 

 

 

 

 

 

 

 

 

 

 

19.0°C

 

 

 

2.05

 

0.48

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19.5°C

2.23

1.61

0.45

2.09

1.55

0.48

1.94

1.49

0.52

1.77

1.42

0.56

 

 

 

 

 

 

 

 

 

 

 

 

 

22.0°C

2.43

1.67

0.46

2.27

1.61

0.49

2.12

1.55

0.52

1.92

1.48

0.57

 

 

 

 

 

 

 

 

 

 

 

 

 

OCS-CE9GKEW CU-CE9GKE

230V

 

 

 

 

 

Outdoor Temp. (°C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor wet

 

30

 

 

35

 

 

40

 

 

46

 

bulb temp.

TC

SHC

IP

TC

SHC

IP

TC

SHC

IP

TC

SHC

IP

 

 

 

 

 

 

 

 

 

 

 

 

 

17.0°C

2.58

1.96

0.54

2.41

1.88

0.58

2.24

1.80

0.62

2.04

1.71

0.67

 

 

 

 

 

 

 

 

 

 

 

 

 

19.0°C

 

 

 

2.60

 

0.59

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19.5°C

2.83

2.05

0.55

2.65

1.97

0.59

2.46

1.89

0.63

2.24

1.80

0.68

 

 

 

 

 

 

 

 

 

 

 

 

 

22.0°C

3.09

2.12

0.56

2.88

2.04

0.60

2.68

1.97

0.64

2.44

1.88

0.70

 

 

 

 

 

 

 

 

 

 

 

 

 

OCS-CE12GKEW CU-CE12GKE

 

230V

 

 

 

 

 

Outdoor Temp. (°C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor wet

 

30

 

 

35

 

 

40

 

 

46

 

bulb temp.

TC

SHC

IP

TC

SHC

IP

TC

SHC

IP

TC

SHC

IP

 

 

 

 

 

 

 

 

 

 

 

 

 

17.0°C

3.47

2.63

0.84

3.24

2.52

0.91

3.02

2.43

0.97

2.74

2.30

1.05

 

 

 

 

 

 

 

 

 

 

 

 

 

19.0°C

 

 

 

3.50

 

0.92

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19.5°C

3.81

2.76

0.86

3.56

2.65

0.92

3.31

2.55

0.99

3.01

2.43

1.07

 

 

 

 

 

 

 

 

 

 

 

 

 

22.0°C

4.15

2.86

0.87

3.88

2.75

0.94

3.61

2.65

1.01

3.28

2.53

1.08

 

 

 

 

 

 

 

 

 

 

 

 

TC

- Total Cooling Capacity (kW)

 

 

 

 

 

 

 

 

 

SHC - Sensible Heat Capacity (kW)

 

 

 

 

 

 

 

 

 

IP

- Input Power (kW)

 

 

 

 

 

 

 

 

 

 

 

Indoor 27°C/19°C

Outdoor 35°C/24°C

20

Page 20
Image 20
Panasonic specifications Sensible Capacity Chart, OCS-CE7GKEW CU-CE7GKE, OCS-CE9GKEW CU-CE9GKE, OCS-CE12GKEW CU-CE12GKE