1.2.CS-CE9GKEW CU-CE9GKE

 

 

ITEM

UNIT

INDOOR UNIT

 

OUTDOOR UNIT

Performance Test Condition

 

EUROVENT

C

Capacity

 

kW

2.60 (0.80 ~ 3.00)

O

 

 

kCal/h

2240 (690 ~ 2580)

O

 

 

 

 

 

 

EER

 

W/W

4.41 (4.57 ~ 4.00)

L

 

 

 

 

 

 

 

kCal/hW

3.80 (3.94 ~ 3.44)

I

 

 

 

 

 

 

 

 

N

Noise Level

 

dB (A)

High 39, Low 25, Q-Lo 21

 

High 46

G

 

 

 

 

 

 

Power level dB

High 50, Low 36, Q-Lo 32

 

59

 

 

 

 

 

 

H

Capacity

 

kW

3.60 (0.80 ~ 5.00)

 

 

 

 

 

E

 

 

kCal/h

3100 (690 ~ 4300)

A

 

 

 

 

 

 

COP

 

W/W

4.31 (4.85 ~ 3.73)

T

 

 

 

 

 

 

 

kCal/hW

3.71 (4.18 ~ 3.21)

I

 

 

 

 

 

 

 

 

N

Noise Level

 

dB (A)

High 40, Low 27, Q-Lo 24

 

High 47

G

 

 

 

 

 

 

Power level dB

High 51, Low 38, Q-Lo 35

 

60

 

 

 

 

 

 

 

Moisture Removal

 

l/h

 

1.6

 

 

 

 

 

 

pt/h

 

3.4

 

 

 

 

 

 

 

 

 

 

 

 

 

Q-Lo

m3/min (ft3/min)

Cooling; 4.9 (170)

 

 

 

Heating; 6.1 (220)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lo

m3/min (ft3/min)

Cooling; 6.6 (230)

 

 

 

Heating; 7.1 (250)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air Volume

Me

m3/min (ft3/min)

Cooling; 7.8 (280)

 

Heating; 8.6 (300)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hi

m3/min (ft3/min)

Cooling; 10.4 (370)

 

Cooling; 29.8 (1050)

 

 

Heating; 11.0 (390)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SHi

m3/min (ft3/min)

Cooling; 10.7 (380)

 

 

 

Heating; 11.4 (400)

 

 

 

 

 

 

 

 

 

 

 

 

 

Refrigeration Control Device

 

 

Check Valve & Capillary Tube

Refrigeration Oil

 

cm3

 

RB68A or Freol Alpha68M (320)

Refrigerant (R410A)

 

g (oz)

 

965 (34.1)

 

 

 

 

 

 

 

 

 

Height

mm (inch)

280 (11-1/32)

 

540 (21-1/4)

Dimension

Width

mm (inch)

799 (31-15/32)

 

780 (30-23/32)

 

 

 

 

 

 

 

 

 

Depth

mm (inch)

183 (7-7/32)

 

289 (11-3/8)

 

 

 

 

 

 

Net Weight

 

kg (lbs)

9 (20)

 

34 (75)

Pipe Diameter

Gas

mm (inch)

9.52 (3/8)

Liquid

mm (inch)

6.35 (1/4)

 

 

 

 

 

 

 

Standard Length

 

m (ft)

7.5 (24.6)

 

 

 

 

Pipe Length Range

 

m (ft)

3 (9.8) ~ 15 (49.2)

 

 

 

 

Height Difference

 

m (ft)

15 (49.2)

 

 

 

 

 

Additional Gas Amount

 

g/m (oz/ft)

 

20 (0.2)

 

 

 

Refrigeration Charge Less

m (ft)

7.5 (24.6)

 

 

 

 

 

 

 

Drain Hose

Inner Diameter

mm

16

 

 

 

 

 

 

Length

mm

650

 

 

 

 

 

 

Type

 

 

Hermetic Motor

Compressor

Motor Type

 

 

Brushless (6-pole)

 

 

 

 

 

 

 

 

 

Rated Output

W

 

700

4

Page 4
Image 4
Panasonic CS-CE12GKEW, CU-CE12GKE, CU-CE7GKE, CS-CE7GKEW specifications CS-CE9GKEW CU-CE9GKE

CS-CE9GKEW, CS-CE12GKEW, CS-CE7GKEW, CU-CE7GKE, CU-CE12GKE specifications

Panasonic's latest range of air conditioning units, including the CU-CE12GKE, CU-CE7GKE, CS-CE12GKEW, CS-CE7GKEW, and CS-CE9GKEW, promises to deliver efficient cooling and heating solutions for residential and commercial environments. These models are a part of Panasonic's commitment to innovation and sustainability, offering advanced features and cutting-edge technologies that enhance user comfort and energy efficiency.

One of the standout features of this range is the inverter technology integrated into these units. The inverter system optimally adjusts the compressor speed and operation, ensuring that the temperature remains constant while minimizing energy consumption. This not only results in lower electricity bills but also reduces the overall environmental impact. By maintaining a stable temperature, the inverter technology enhances the comfort level within any space.

Another key characteristic of these models is their compact design, making them suitable for a variety of installation settings. The indoor units boast sleek aesthetics that seamlessly blend with modern interior designs while providing powerful performance. They come equipped with advanced air filtration systems that enhance indoor air quality by eliminating dust, allergens, and other particles, ensuring a cleaner and healthier atmosphere for occupants.

The CU-CE12GKE and CU-CE7GKE models are particularly noted for their robust cooling capacities, making them ideal for medium to large-sized rooms. The CS-CE12GKEW, CS-CE7GKEW, and CS-CE9GKEW models, featuring a range of cooling capacities, cater to diverse space requirements, making them versatile for various environmental needs.

Additional features include a quiet mode operation, which ensures minimal noise disruption, essential for bedrooms and workspaces. These units come equipped with user-friendly controllers that provide easy temperature adjustments and settings, ensuring optimal comfort levels. The energy-efficient design and advanced technologies, including R32 refrigerant, contribute to lower carbon footprint without compromising on performance.

In conclusion, the Panasonic CU-CE12GKE, CU-CE7GKE, CS-CE12GKEW, CS-CE7GKEW, and CS-CE9GKEW air conditioning units represent a significant advancement in climate control technology. With their innovative features, energy efficiency, and sleek design, they are well-suited to meet the demands of users looking for reliable and effective air conditioning solutions.