Using Web Browser Control

Contents of mail sent

Mail with the contents shown below is sent when the E-mail settings have been established.

=== Panasonic projector report(CONFIGURE) ===

Projector Type

 

: D5700

 

 

 

 

----- E-mail setup data -----

 

 

 

 

 

TEMPERATURE WARNING SETUP

 

 

 

MINIMUM TIME

at [ 60] minutes interval

 

INPUT AIR TEMPERATURE Over [ 45C / 113F ]

ERROR

 

 

 

 

[ ON ]

 

 

LAMP1 RUNTIME

 

 

[ ON ]

at REMAIN [ 100] H

LAMP1 RUNTIME

 

 

[ ON ]

at REMAIN [ 200] H

LAMP2 RUNTIME

 

 

[ ON ]

at REMAIN [ 300] H

LAMP2 RUNTIME

 

 

[ ON ]

at REMAIN [ 400] H

INPUT AIR TEMPERATURE

[ OFF ]

 

 

PERIODIC REPORT

 

 

 

 

 

Sunday

[ ON ]

Monday

[ OFF ]

Tuesday

[ ON ] Wednesday [ OFF ]

Thursday

[ ON

]

Friday

[ OFF ]

Saturday [ ON ]

00:00 [ ON ]

01:00 [ OFF ]

02:00 [ ON ]

03:00 [ OFF ]

04:00 [ OFF ]

05:00 [ ON ]

06:00 [ OFF ]

07:00 [ ON ]

08:00 [ ON ]

09:00 [ OFF ]

10:00 [ ON ]

11:00 [ OFF ]

12:00 [ OFF ]

13:00 [ ON ]

14:00 [ OFF ]

15:00 [ ON ]

16:00 [ ON ]

17:00 [ OFF ]

18:00 [ ON ]

19:00 [ OFF ]

20:00 [ OFF ]

21:00 [ ON ]

22:00 [ OFF ]

23:00 [ ON ]

----- check system -----

 

 

 

MAIN CPU BUS

[

OK

]

FAN

[

OK

]

OPTICS MODULE TEMPERATURE

[

OK

]

INPUT AIR TEMPERATURE

[

OK

]

AROUND LAMP TEMPERATURE

[

OK

]

LAMP2 REMAIN TIME

[

OK

]

LAMP1 REMAIN TIME

[

OK

]

 

 

 

 

 

 

 

 

 

Mail with the contents shown below is sent when an error has occurred.

=== Panasonic projector report(ERROR) ===

 

Projector Type

: D5700

 

 

 

––––– check system –––––

 

 

 

MAIN CPU BUS

 

 

[

OK

]

FAN

 

 

[

OK

]

OPTICS MODULE TEMPERATURE

[

OK

]

INPUT AIR TEMPERATURE

[

OK

]

AROUND LAMP TEMPERATURE

[

OK

]

LAMP2 REMAIN TIME

 

[

OK

]

LAMP1 REMAIN TIME

 

[

OK

]

LAMP2 STATUS

 

 

[

OK

]

LAMP1 STATUS

 

 

[

OK

]

SHUTTER

 

 

[ FAILED ]

AIR FILTER

 

 

[

OK

]

OPTICS MODULE TEMP.SENSOR

[

OK

]

INPUT AIR TEMP.SENSOR

[

OK

]

AROUND LAMP TEMP.SENSOR

[

OK

]

BATTERY

 

 

[

OK

]

AIRFLOW SENSOR

 

 

[

OK

]

COLOR WHEEL

 

 

[

OK

]

COVER OPEN

 

 

[

OK

]

(Error code 00 10 00 00 00 00 00 00)

 

 

 

Input air temperature

: 30 degC /

86 degF

 

Optics module temperature : 30 degC / 86 degF

 

Around lamp temperature : 37 degC / 98 degF

 

SET RUNTIME

 

30 H

 

 

 

POWER ON

 

33 times

 

 

 

LAMP1 ON

 

34 times

 

 

 

LAMP1 LOW

 

25 H

 

 

 

LAMP1 HIGH

 

5 H

 

 

 

LAMP2 ON

 

24 times

 

 

 

LAMP2 LOW

 

16 H

 

 

 

LAMP2 HIGH

 

4 H

 

 

 

LAMP1 REMAIN

1476 H

 

 

 

LAMP2 REMAIN

1484 H

 

 

 

----- Network configuration -----

IP address 192.168.0.8

MAC address 00:00:00:00:00:00 Thu Mar 02 14:11:02 2006

----- Memo -----

Adjust clock page

Click [Network set up], then [Adjust clock] to display the Adjust clock page.

Time zone selection

Button to update time zone setting

New date field

Button to update time and date settings

New time field

Note

• If the time becomes incorrect immediately after setting the correct time, then the battery needs to

 

be changed. Contact the dealer where you bought the projector to have the battery changed.

48

Page 48
Image 48
Panasonic DW5100UL, PT-D5700UL, PT-DW5100U operating instructions Contents of mail sent, Adjust clock