•You can select from 30 torque clutch settings (1 to 30).
•Use figures from the Tightening Torque Chart to guide your selection of torque clutch setting. (See the following tighten- ing torque chart)
2.Press the OK button to accept the select- ed torque clutch setting.
•The control panel will stop flashing and light up.
CAUTION:
•You must press the OK button in order for the selected setting to take effect.
•Be sure to verify the new value after changing the setting. (See page 14.)
Setting the snug point detection level
(1)
(2)
(3)
1.Press the torque setting mode button.
•The snug point detection level setting value will be displayed.
Display
Battery indication lamp
2.Press the and buttons to set the best snug point detection level for the work you’re performing.
Display | Snug point detection level | |
| Low | |
L1 | (Use for work characterized by | |
low loads before the snug point | ||
| ||
| is reached.) | |
| High | |
L2 | (Use for work characterized by | |
high loads before the snug point | ||
| ||
| is reached.) |
3.Press the OK button to accept the number of torque stages and the snug point detec- tion level.
•The tool’s panel will flash and then light up continuously.
CAUTION:
•Set the snug point detection level from “L1.” Setting the snug point detection level from “L2” may result in cracking or defor- mation of the target material.
•If the tool stops before the snug point at snug point detection level “L1,” set the snug point detection level to “L2.”
•Changing the snug point detection level from “L1” to “L2” may increase the torque. Set the number of torque stages again after making this change.
•The setting will not be changed until you press the OK button.
•After changing the setting, be sure to check the new setting value. (See page 14.)
IMPORTANT INFORMATION:
•You can set the snug point detection level and retightening prevention time at the same time by changing the retight- ening prevention time (see page 13) before pressing the OK button and then pressing the OK button.
•Pressing the torque setting mode but- ton toggles the display between the snug point detection level setting value and the number of torque stages set- ting value.
•The tool ships with the snug point detection level set to “L1.”
•When the number of torque stages has been set as shown below, the snug point detection level cannot be switched from “L1” to “L2.”
Model | Number of torque stages | |
setting | ||
| ||
EZFLA4 | 1 to 8 | |
EZFLA5 | 1 to 3 |
- 12 -