(Cooking area)
Do not install above or inside this area

GENERAL SAFETY INFORMATION

1. Do not install this ventilating fan where interior room temperature may exceed 104F (40C).

2.

Make sure that the electric service supply voltage is AC 120V, 60Hz.

Prohibited

3.

Follow all local electrical and safety codes, as well as the National Electrical Code

 

 

(NEC) and the Occupation Safety and Health Act (OSHA).

 

4.

Always disconnect the power source before working on or near the fan, motor,

Prohibited

 

light fixture or junction box.

 

 

5.

Protect the power cord from sharp edges, oil, grease, hot surfaces, chemicals or

 

 

other objects.

 

6.

Do not kink the power cord.

Prohibited

7.

Do not install the unit where ducts are configured as shown in Fig.A.

Adaptor

8. Provide suction parts with proper ventilation.

9. This unit is UL listed for use over a bathtub or shower when installed in a GFCI

Prohibited

protected branch circuit.

 

10. This product has a fluorescent lamp that contains mercury.Disposal may be regulated

in your community due to environmental considerations.For disposal or recycling information,please contact your local authorities or the Electronics lndustries Alliance:http://www.eiae.org

Fig.A

CAUTION:

1.For general ventilating use only.Do not use to exhaust hazardous or explosive materials and vapors.

2.Not for use in cooking area.(Fig.B)

3.This product must be properly grounded.

Cooking Floor equipment

Fig.B

WARNING:

To reduce the risk of fire,electric shock or injury to persons,observe the following:

1.Use this unit only in the manner intended by the manufacturer.if you have any questions,contact to the manufacturer.

2.Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards,including fire-rated construction.

3.Sufficient air is needed for proper combustion and exhaustiong of gases through the flue(chimeny) of fuel burning equipment to prevent back drafting.Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA),and the American Society for Heating Refrigeration and Air Conditioning Engineers (ASHRAE)and the local code authorities.

4.When cutting or drilling into wall or ceiling,do not damage electrical wiring and other hidden utilities.

5.Ducted fans must always be vented to the outdoors.

6.Do not use this unit with any solid-state control device.Solid state controls may cause harmonic distortion which can cause motor humming noise.

7.Before servicing or cleaning unit,switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally,When the service disconnecting means cannot be locked,securely fasten a prominent warning device,such as a tag,to the service panel.

8.If this unit to be installed over a tub or shower,it must be marked as appropriate for the application and be connected to a GFCI(Ground Fault Circuit Interrupter)-protected branch circuit.

9.Not to be installed in a ceiling thermally insulated to a value greater than R40.(This is required for installation in Canada only.)

7

Page 7
Image 7
Panasonic FV-08VKML2, FV-08VKSL2 installation instructions General Safety Information

FV-08VKML2, FV-08VKSL2 specifications

The Panasonic FV-08VKML2 and FV-08VKSL2 are exceptional bathroom ventilation fans designed to provide efficient airflow while maintaining energy efficiency and low noise levels. These models are part of Panasonic's WhisperCeiling Series, renowned for their superior performance and innovative features.

One of the standout characteristics of both models is their powerful yet quiet operation. With a sound level of just 0.3 sones, these fans are among the quietest in the market. This means that even when in use, they won't disturb your peace, making them ideal for areas where calm and quiet are essential.

The FV-08VKML2 model is equipped with a 100 CFM airflow capability, ensuring effective ventilation in bathrooms up to 95 square feet. In comparison, the FV-08VKSL2 offers the same airflow capacity but comes with additional features tailored for more specific applications. Both fans utilize Panasonic's ECM motor technology, which enhances energy efficiency and reduces power consumption, contributing to lower utility bills and a smaller environmental footprint.

Another significant feature of these models is the built-in smart plug and humidity sensor in the FV-08VKML2. This technology automatically activates the fan when humidity levels rise, making it perfect for preventing mold and mildew in damp environments. The FV-08VKSL2, on the other hand, provides a more standard operation without the humidity sensing capability, appealing to users who prefer manual control.

Both models are constructed with high-quality materials that ensure durability and a long lifespan. The fans are designed for easy installation; the low-profile design allows them to fit seamlessly into various ceiling spaces, and the included mounting brackets make setup straightforward.

The Panasonic FV-08VKML2 and FV-08VKSL2 also emphasize ease of maintenance. The units feature washable filters that capture dust and debris, ensuring that air quality remains high without requiring constant replacements.

In conclusion, the Panasonic FV-08VKML2 and FV-08VKSL2 are high-performance bathroom ventilation solutions that combine efficiency, quiet operation, and smart technologies to enhance air quality. Whether you're looking for automatic humidity control or a straightforward fan, these models cover a range of user needs while providing reliable ventilation for any bathroom space.