Initialization Pulse Adjustment

Initialization Pulse Adjustment

1.Input a 100% White signal to the unit.

2.Set the picture controls as follows: Picture menu : Vivid Normal : Set

Aspect : Full

3.Connect an Oscilloscope to test point TPSC1. Using VR6602, adjust (T2) for 195+/- 10µ Sec.