1.1 Safety Instructions
3
- the current consumption of the system does not exceed the value stated on the
product label.
Switch off and ensure that the device cannot be operated if the following apply
because safe operation may no longer be possible:
- the device has visible damages or
- the device is no longer functioning
Additional safety instructions for DC power supply circuits
To guarantee safe operation of devices with DC power supply voltages greater than 60V DC or a power
consumption larger than 240VA, please observe that:
- the device is set up, installed and operated in a room or enclosure marked with
“RESTRICTED ACCESS” if there are no safety messages on the device itself
such as safety signs or labels.
- no cables or parts without insulation in electrical circuits with dangerous voltage or
power should be touched directly or indirectly
- a reliable protective earthing connection is provided
- a suitable, easily accessible disconnecting device is used in the application (e.g.
overcurrent protective device) if the device itself cannot be disconnected
- a disconnect device, if provided in or as part of the equipment, shall disconnect
both poles simultaneously
- interconnecting power circuits of different devices cause no electrical hazards
A sufficient dimensioning of the power cable wires must be selected – according to the
maximum electrical specifications on the product label – as stipulated by EN60950-1
or EN60204 or UL508 regulations.
The devices do not generally fulfill the requirements for “centralized DC power
systems” (UL 60950-1, Annex NAB; D2) and therefore may not be connected to such
devices!