GN Series Hardware Manual
3.9 Mounting the System to a Subframe or Panel
37
The mounting clamps enable easy, fast mounting of the GN unit onto an instrument panel or
wall panel.
Item GN07 GN10 GN12 GN15
Rear side enclosure
(W x H x D, mm)
215 x 146.3 x 45.75 295 x 234 x 44 324 x 263 x 49.5 406.4 x 311 x 50
Panel cutout
(W x H, mm)
217 x 148 297 x 236 326 x 265 408 x 313
Metal mounting panel
thickness (mm)
1.5 – 6 1.5 – 6 1.5 – 8 1.5 – 8
Mounting clamps with
screws
4 x
8 x 6 x 8 x
Required tool Allen wrench 2mm
Proper torque Tighten the screws with a torque of 0.5•Nm
Mounting position Ensure the vertical and horizontal alignment of the system.
NOTE
• In order to ensure IP65 front sealing against dust and water, mount the
system on a non-textured surface. Before you install the GN unit on a panel
or a subframe for a switching cabinet, verify that the seal on the rear of the
front plate is in perfect condition. The seal has to be in place without
defects and dirt.
• When you install the GN07 on a panel or a subframe for a switching cabinet,
leave enough free space at the rear top side to insert or remove the CF card.
To mount the system to a subframe or to a panel, proceed as follows:
1.
2.
3.
Procedure
1. Assemble the mounting clamps with the Allen screws included
2. Depending on the dimension of the display enclosure of your system, cut a
hole in the panel/subframe
Refer to the tables for the panel cut-out dimensions. The panel where you intend
to attach the system must be accessible from both the front and the rear side. The
system must be turned off and disconnected from the power supply and
peripheral devices
3. Insert the system into the panel cut-out from the front
In order to ensure the protection class IP65 on the front after installation, the
contact surface with the seal must be clean and flush.
4. Ensure the vertical and horizontal alignment of the system
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net