A - IDENTIFICATION OF MAIN PARTS

A)Turbine nozzle (MC-CG663, MC-CG663K only)

B)Floor nozzle (MC-CG661, MC-CG661K only)

C)Connection pipe

D)Hose

E)Suction regulator

F)Curved wand

G)Telescopic wand (MC-CG663, MC-CG663K)

(MC-CG661, MC-CG661K)

H)Hose inlet

I)Dust indicator

J)Dust cover

K)ON/OFF Switch pedal

L)Cord rewind pedal

M)Crevice nozzle

N)Dusting brush

O)Parquet floor nozzle (MC-CG661, MC-CG661K only)

P)Exhaust cover

Q)Plug

R)Variable power control button

B - HOW TO ASSEMBLE YOUR CLEANER

B-1Insert connection pipe into hose inlet until it locks. When removing hose assembly, pull out connection pipe with pushing down two connection buttons. NOTE: Do not bend, pull, and step on the hose or put

anything heavy on it.

B-2Insert the hose unit into the upper end of the connected telescopic wand, and the floor nozzle to the other end. (Only MC-CG661, MC-CG661K)

B-3Insert the hose unit into the upper end of the telescopic wand.

Twist the telescopic wand so that the round hole will fit into the tab on the hose unit. (When removing the hose, push the tab down whilst pulling on the telescopic wand)

Attach the Turbine Nozzle to the other end (Only MC- CG663, MC-CG663K)(Removal as per reverse procedure)

B-4Keep hold of the wand grip and pull out the wand to the required length.

4

C - HOW TO OPERATE YOUR CLEANER

C-1 Pull out the mains lead and put the plug into the wall socket.

C-2 Gently press at the center of the switch pedal to turn ON the vacuum cleaner.

Press the pedal again to turn it OFF.

C-3 Power control

To increase or decrease the power, turn the variable power control.

C-4 Switching between carpet and flooring

Flooring: Press lever A

Carpet: Press lever B

*Switching 3 positions for MC-CG663, MC-CG663K.

Flooring (PARQUET): Set position A

Carpet (short): Set position B

Carpet (long or hard to push): Set position C

C-5The curved wand of the hose is attached with a manual suction regulator, which allows you to briefly reduce the suction level.

C-6 After you finish vacuuming, remove the plug from the wall socket and press the cord rewind pedal.

When rewinding the mains lead, press at center of rewind pedal by holding the plug so that it does not become damaged.

C-7 Storage position

Insert the wand holder straight into the wand supporter.

C-8 Park system

For short breaks during vacuuming, slide the hook attached to the nozzle pipe into the slot on the rear side of the cleaner.

NOTE: When you use park position, we suggest the appliance is switched off.