Replacing Agitator

Replacing Agitator

Base Plate

Belt Guard

Base Plate Belt Guard Protector de la correa de la placa de la base

Turn the vacuum cleaner over to check for worn brushes.

When brushes are worn to the level of the base belt guard, replace the agitator.

Remove lower plate and agitator.

Position belt over belt pulley on the new agitator.

Reinstall agitator and lower plate.

Cleaning Agitator

Clean agitator after every five uses and every time the belt is replaced.

Remove lower plate.

Cut off any carpet pile and lint entangled around agitator with a pair of scissors.

Remove agitator.

Remove any string or debris located on the end caps.

Reinstall agitator and lower plate.