12

3.7. Motor Protector Replacement

3.7.1. Removal

1. Remove the seven (7) screws that secure the dust cover
and remove the dust cover.
2. Remove the motor protector located inside the dust com-
partment by pushing in on the two retaining tabs. Do one
side at a time while pushing out on the motor protector
from inside the dust compartment.
3. Once the motor p rotecto r has be en remo ved it c an be di s-
assembled for replacement of parts.

3.7.2. Installation

1. Reinstall the motor protector into the dust compartment
by align ing the two t abs under th e top fla nge with t he slo ts
in the dust compartment by applying pressure from the
back of the vacuum until it snaps into place.
2. Install the dust cover by first ensuring all wiring is routed
correctly so that no wires may be pinched during assem-
bly.
NOTE: For gen eral servicing, i t is ne ces sary to el im inate pinch-
ing of any wire during reassembly. After servicing any electrical
component or electrical enclosure, the unit should be reassem-
bled and checked for dielectric breakdown or current leakage.