LOWER PLATE REMOVAL/INSTALLATION

 AGITATOR ASSEMBLY REMOVAL/INSTALLATION LOWER PLATE REMOVAL/INSTALLATION

 BELT REPLACEMENT AGITATOR ASSEMBLY REMOVAL/INSTALLATION

Removal

1.Place the handle in the upright position.

2.Turn the vacuum cleaner over exposing the underside. Release the lower plate by pressing inward the two (2) latches and depressing the two locking tabs that secure the lower plate, (Fig. 1).

3.Remove the lower plate and remove any residue that may exist in the belt area.

Installation

(Fig. 1)

Removal

The brushes are replaceable separately. When the brushes need replacing, the agitator assembly will have to be removed.

1. Remove the lower plate as outlined in the LOWER PLATE REMOVAL/ INSTALLATION section.

2.Carefully lift up on the agitator assembly until it clears both sides of the nozzle housing,

(Fig. 2).

(Fig. 2)

1. Hook the front of the lower plate into the slots on the front of the nozzle housing. Press the lower plate down until the

locking tabs snap into place.

3. Remove the belt from the motor shaft by sliding it off between the end of the shaft and the nozzle housing.

2. Press outward on the two (2) lower plate latches to fasten.

NOTE: For general servicing, it is necessary to eliminate pinching of any wire during reassembly. After servicing any electrical component or electrical enclosure, the unit should be reassembled and checked for dielectric breakdown or current leakage.

Installation

1.Place the belt around the motor shaft, (Fig. 3).

2.Start the agitator assembly back into the nozzle housing by placing the side opposite the belt partially into the slot. This will hold the agitator in place and leave both hands free to place enough tension on the belt to allow that side of the agitator to return to the nozzle housing slot.

3.Place the belt around the agitator pulley on the agitator assembly.

Motor Shaft

(Fig. 3)

NOTE: There is a place for the belt to fit on one end of the agitator assembly only. This is the agitator pulley.

4. Use both hands to pull the belt tight, (Fig. 4), and slide the agitator assembly firmly into the slots on each end of the nozzle housing.

5Rotate the agitator assembly by hand to insure nothing rubs and to check

for correct assembly.

6. Replace the lower plate as outlined in the LOWER PLATE

(Fig. 4)

REMOVAL/INSTALLATION section.

 

Manual background BELT REPLACEMENT

Removal

1.Follow all of the removal instructions outlined in the AGITATOR ASSEMBLY REMOVAL/INSTALLATION section.

Installation

2.Place the new belt around the motor shaft and follow the installation instructions in the AGITATOR ASSEMBLY REMOVAL/INSTALLATION section.

- 10 -

- 11 -

Page 10
Image 10
Panasonic MC-V5203 Lower Plate Removal/Installation, Agitator Assembly Removal/Installation, Belt Replacement