EXPLODED VIEW (MOTOR FAN ASSEMBLY)

 PARTS LIST (MOTOR FAN ASSEMBLY) EXPLODED VIEW (MOTOR FAN ASSEMBLY)

1

2

3

4

5

6

7

8

9

 NOZZLE HOUSING AND SHORT HOSE REPLACEMENT PARTS LIST (MOTOR FAN ASSEMBLY)

Ref. No.

Part Name & Description

Part No.

Quantity

Remarks

1

Fan Case

AMC53F-AVØØU

1

 

2

Nut

AMC33F-ACØØU

1

 

 

 

 

 

 

3

Washer

AMC62F-AVØØU

1

 

 

 

 

 

 

4

Fan

AC98FRFZØØ

1

 

5

Washer

AC62FRFZØØ

1

 

 

 

 

 

 

6

Spacer

AC6ØFRFZØØ

1

 

7

Brush Assembly

AC27FRFZØØ

1(Set)

 

8

Bracket

ACØ2DV3ZØU

2

 

 

 

 

 

 

9

Screws

AC4ØDV3ØØU

4

 

 

 

 

 

 

over as the motor may fall out. NOZZLE HOUSING AND SHORT HOSE REPLACEMENT

Removal

 

1.

Remove the lower plate as outlined in the LOWER

 

PLATE REMOVAL/INSTALLATION section.

 

2.

Remove the belt and agitator assembly as outlined in

 

the respective sections.

 

3.

Remove the nozzle hose by pulling it up out of the

 

nozzle housing and then pulling it, while twisting, out of

 

the wand holder.

 

4.

Insert a flat blade screwdriver between the nozzle

(Fig. 10)

housing and the plastic shaft, pry out the plastic shaft as

 

illustrated, (Fig. 10).

 

5. Remove the nozzle housing as illustrated, (Fig 11).

6. Remove the handle release assembly as outlined in its removal section.

7.Remove the light cover, (Fig. 12) by removing the two (2) screws from

the nozzle housing and pushing out on the cover (Fig. 12).

8. Remove window, furniture guard and slider support.

NOTE: If the motor case cover is removed, DO NOT turn vacuum

 

(Fig.11)

over as the motor may fall out.

 

 

Installation

Handle Release

Cover

 

 

Light

1. Install the light cover, handle release assembly, furniture guard,

Assembly

 

 

 

window and slider support in the new nozzle housing. (Fig. 12).

 

 

2. Fit the nozzle from the motor shaft side first and rotate it into

Furniture

 

place on the dust container as illustrated, (Fig. 13).

Guard

 

 

 

3.Slide the plastic shaft through the nozzle housing and into the dust container. Make sure that the slot on the bottom of

the plastic shaft is down and fitted onto the projection.

Light Cover Screws

4. Reassemble the nozzle hose by inserting it into the wand holder

(Fig. 12)

 

then place the other end into the nozzle housing with the tab fitting into the slot.

 

5.Install the belt, agitator assembly, and the lower plate according to the respective instructions.

- 8 -

(Fig. 13)

Plastic

Shaft

Nozzle

Housing

Projection

(Fig. 14)

- 13 -

Page 8
Image 8
Panasonic MC-V5203 Nozzle Housing And Short Hose Replacement, Parts List Motor Fan Assembly, Removal, Installation