The amplifier and motor should be properly installed to avoid failures, mechanical damages and injuries.

Amplifier

Location

Indoors, where the amplifier is not subjected to rain water and direct sun beams. Note
that the amplifier is not a waterproof structure.
Avoid the place where the amplifier is subjected to corrosive gases, flammable gases,
grinding liquids, oil mists, iron powders and cutting particles.
Place in a well-ventilated, and humid- and dust-free space.
Place in a vibration-free space.

Environmental Conditions

How to Install

This is a rack-mount type.
Place the amplifier vertically. Allow enough space surrounding for ventilation.
Front panel mount type (recessed)
Item
Ambient temperature
Ambient humidity
Storage temperature
Storage humidity
Vibration
Altitude
Conditions
0 to 55˚C (free from freezing)
Not greater than 90%RH (free from condensation)
-20 to 80˚C (free from condensation)
Not greater than 90%RH (free from condensation)
Not greater than 5.9m/s2 (0.6G) at 10 to 60 Hz
Not greater than 1000 m
Earth connection (M4 screw) tightening torque
shall not exceed 0.39 ~ 0.59 N·mU.U