-16-
Installation

Motor

Location

Indoors, where the amplifier is not subjected to rain water and direct sun beams.
• Avoid the place where the amplifier is subjected to corrosive gases, flammable gases,
grinding liquids, oil mists, iron powders and cutting particles.
• Place in a well-ventilated, and humid- and dust-free space.
• Easy maintenance, inspections and cleaning is also important.

Environmental Conditions

How to Install

The motor can be installed either vertically or horizontally. Observe the following notes.
• Horizontal mounting
Place the motor with the cable outlet facing down to prevent the entry of oil and water.
• Vertical mounting
• If a motor is coupled with a reduction gear, use a motor equipped with oil seal so that oil
in the reduction gear may not enter into the motor.
Item
Ambient temperature
Ambient humidity
Storage temperature
Storage humidity
Vibration
Shock
Conditions
0 to 40˚C (free from freezing)
Not greater than 85%RH (free from condensation)
-20 to 80˚C (free from freezing)
Not greater than 85%RH (free from condensation)
Cable Motor
Oil and water

Oil and Water Protections

• This motor(IP65 rating) can be used where it is subjected
to water and/or oil drops, but is not water - or oil - proof.
Therefore, the motors should not be placed or used in
such environment.
If the motor is coupled with a reduction gear, use the motor
with oil seals to prevent the reduction gear oil from
entering into the motor.
Don't use the motor with the cables being immersed in oil
or water.
49 m/s2 (5G) or less at rotation, 24.5 m/s2 (2.5G) or less at rest
High precision and normal type: 24 m/s2 (2G) or less
Standard type: 49 m/s2 (5G) or less
98 m/s2 (10G) or less
High precision and normal type: 98 m/s2 (10G) or less
Standard type: 24 m/s2 (2G) or less
Motor only
With gear
(At rotation)
Motor only
With gear