- App.18 -
Details of Parameters
PrNo. Parameter
Value
Function
For linear motion or other similar motion, overtraveling of the work may cause
mechanical damages. To avoid this, it is necessary to provide limit switches at
each end so that traveling over the limit switch position can be inhibited.
<Notes>
1.
With Pr04 = 0 and CCW/CW off (not connected to COM-),
the amplifier will stop the motor with "overtravel limit
input error" assuming that traveling over the limit occurs
in both the CCW and CW directions.
2.
You can specify whether or not to use the
dynamic brake during deceleration after CCW
or CW overtravel limit input (CCWL or CWL)
becomes active. For details, see the description
of Pr66 (DB inhibition at overtravel limit).
04 Overtravel
input inhibit 0 ~ 1
CW direction CCW direction
CCWL
CWL
Work
Servo
motor Limit
switch Limit
switch
Amplifier
CCWL/CWL
input
Enabled
Disabled
Input
CCWL
(CN I/F-8-pin)
CWL
(CN I/F-7-pin)
Operation
Normal with the CCW limit
switch not activated
Normal with the CW limit
switch not activated
Connection to COM-
Close
Open
Close
Open
Both the CCWL and CWL inputs are disabled, and traveling
in both the CW and CCW directions are allowed.
Traveling in CCW direction inhibited
Traveling in CW direction inhibited
Default setting is shown by [ ].
Value
0
[ 1 ]