Panasonic Protocol Converter Manual V10.2 5Mar 09 Page 6/16
Internal view showing switches V12 Software
Data IN
2 WIRE
TRA TA
TRB TB
4 WIRE
TRA RA
TRB RB
RA TA
RB TB
Data OUT
TRA = A/+
TRB = B/-

SW5 Camera Range

RS232 DIAGNOSTICS PORT
123456 78
VCL - 9600,N,8,1

SW4 Output Protocol

123456 78
PELCO P – 9600,N,8,1
123456 78
PELCO P – 4800,N,8,1
123456 78
PELCO P – 2400,N,8,1
1 - 8
1234
9 - 16
1234
17 - 24
1234
25 - 32
1234
97 - 99
1234

SW5/1-4 Camera range SW5/8

Panasonic Baud

9600
8
19200
8
123456 78
DENNARD – 9600,N,8,1
33 - 40
1234
41 - 48
1234
49 - 56
1234
57 - 64
1234
65 - 72
1234
73 - 80
1234
81 - 88
1234
89 - 96
1234
123456 7 8
VICON – 4800,N,8,1
123456 7 8
VICON – 9600,N,8,1

LD1 = Dome RS422/485 out

LD2 = Panasonic RS422/485 in

LD3 = Checksum ERROR or

command for camera out of range

LD5 = Converter Mode

LD6 = Not used

Data OUT
TRA/TRB
Data OUT
TRA/TRB
Data OUT
TRA/TRB
Data OUT
TRA/TRB
Data OUT
TRA/TRB
Data OUT
TRA/TRB
Data OUT
TRA/TRB
Data OUT
TRA/TRB
ON
12345678
SW3
SW1 SW2
00007-6 LD5
J16
SW4 SW 5
star_
v*.
vhd
PANA
CON
V**
ON
12345678
ON
12345678
ON
12345678
LD1
LD2
LD3
LD6
LD4
SW3/8
ON = 2 WIRE
OFF = 4 WI RE
SD MICRO
Must be fi tted
ON
12345678
123456 78