When [FAILED] has appeared for an item

Parameter

Description

 

 

MAIN CPU BUS

Trouble has occurred in the microcomputer circuitry. Consult your dealer.

FAN

Trouble has occurred in the fan or its drive circuit. Consult your dealer.

OPTICS MODULE

The temperature inside the projector is high. It may be that the projector is

TEMPERATURE

being used where the ambient temperature is high such as near a heating

 

appliance.

INPUT AIR TEMPERATURE

The input air temperature is too high. It may be that the projector is being

 

used where the ambient temperature is high such as near a heating

 

appliance.

AROUND LAMP

The temperature near the lamp has risen very high.

TEMPERATURE

Something may be blocking the exhaust vent.

LAMP REMAIN TIME

The lamp runtime has exceeded the prescribed cumulative time, and it is

 

now time to replace the lamp.

LAMP STATUS

The lamp has failed to light.

 

Wait a short while for the lamp to cool off, and then turn on the power.

SHUTTER

Trouble has occurred in the shutter circuitry. Consult your dealer.

AIR FILTER

Too much dust accumulates on the air filter.

 

Turn off the MAIN POWER switch using the procedure on page 24 and

 

clean the air filter (refer to page 42).

OPTICS MODULE TEMP.SENSOR

Trouble has occurred in the temperature detection sensor inside the

 

projector. Consult your dealer.

INPUT AIR TEMP.SENSOR

Trouble has occurred in the sensor used to detect the input air temperature.

 

Consult your dealer.

AROUND LAMP

Trouble has occurred in the temperature detection sensor around lamps.

TEMP. SENSOR

Consult your dealer.

BATTERY

The backup battery has been run out. Consult your dealer.

AIRFLOW SENSOR

Trouble has occurred in the air volume sensor. Consult your dealer.

COLOR WHEEL

Trouble has occurred in the color wheel or the color wheel drive circuit.

 

Consult your dealer.

 

 

E-mail setup page

With this projector, if a problem occurs or if the lamp usage time reaches a set value, an e-mail message can be sent to one or more preset e-mail addresses (maximum two addresses). Click [Projector Control], then [E-mail set up] to display the E-mail setup page.

The user can modify the threshold temperature for sending temperature warning mail. If the temperature rises above the set value, control sends temperature warning mail.

Select “Enable” to use the E-mail function.

Enter the IP address or server name of the E-mail server (SMTP). The DNS server must be set if the server name is entered.

Enter the E-mail address of the projector. (maximum 63 characters)

The user can enter the location of, for example, the installed projector so that the recipient may easily identify the originator of the E-mail.

(maximum 63 characters)

The user can modify the minimum time interval of temperature warning mail. The default value is 60 minutes. In this case, the user cannot send another mail for 60 minutes after sending previous temperature warning mail even the set warning temperature is reached again.