3/62
Response (Callback) of the basic control command
In the period when commands can be accep ted
Differs ac cording to each command.
In the period when commands cannot be ac cepted
Hexadecimal 02h 45h 52h 34h 30h 31h 03h
Character E R 4 0 1
In case of the parameter error
Hexadecimal 02h 45h 52h 34h 30h 32h 03h
Character E R 4 0 2
Notes when two or more projectors are used
Make the communication conditions the sam e b etw e en o utput /input . I N an d OU T can b e i nd epende ntl y
set respectively. (When you set RS-422 OUT of the fi rst projector to 38 400 bps, s et RS-422 I N of the
second projector to 38 400 bps.)
Make only one in VPS SYSTEM MASTER and make all of the remainder VPS SYSTEM SLAVE.
Set ID number different in each projecto r.
I/O to RS-422 OUT is not done during M AIN POWER OFF. Turn on MAIN POW ER of all projectors.
Make only one of the each group in GROUP MASTER and make all the remainde r-GROUP SLAVE.
Attention:
No command may be sent or received for 10 to 60 seconds a fter the lam p starts lightin g. Try sendi ng
any command after that period has elapsed .
When sending several commands, be sur e to w ait f or a r espons e from the projector, and send the next
command after 0.5 seconds or more pass.
It might take time by the time t he response returns because the co mmand is processed in the projecto r.
Set the time-out to ten seconds or more.
Notes:
This projector will respond to the computer only in the following cases:
If the s e nt ID coincides with the projector ID,
VPS SYS TEM in RS232C settings of this projector is MASTER and the sent ID is ALL, or
If- Group (A—Z) of the sent ID coincides with G ROUP in RS232C settings of this projecto r and
GROUP in RS232C settings of this project or is MASTER.
When the command is receive d during STNDBY, this projector returns the receiving command as it is as
a response (callback) if it is in the period w hen t he concerned command cannot be acc epted.
Each setting/query command conce rning P IN P controls to information on the user being set by current
P IN P setting. Therefore, ER401 is returned as a response (callback) when P IN P setti ng is OFF.