IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

Read these operating instructions carefully before using the unit. Follow the safety instructions on the unit and the safety precautions listed below. Keep these operating instructions handy for future reference.

Getting started

Safety

1.Power source—Connect the unit to a power source of the type described in these instructions or as marked on the unit.

2.Polarization—The unit is equipped with a polarized power plug where one blade is wider than the other. This safety feature en- sures that the plug fits into your household AC outlet only one way. If the plug doesn’t fit one way, try reversing it. If the plug still doesn’t fit, contact an electrician to replace the obsolete out- let. Do not attempt to defeat the safety purpose of the plug.

3.Power cord protection—Route the AC power supply cord so that it will not be walked on or pinched by items placed on or against it. Never take hold of the plug or cord with wet hands. Always grasp the plug body firmly when connecting and discon- necting it.

4.Overloading—When connecting the AC power supply cord, be careful not to overload the household AC outlet, extension cord, or outlet from any other device as this can result in fire or elec- tric shock.

5.Nonuse periods—Turn the unit off when it is not in use. Unplug the unit from the household AC outlet if it is not to be used for a long time. Unplug the unit during lightning storms.

6.Attachments and accessories—Use only the attachments and accessories recommended in these operating instructions.

Installation

Placement

1.Ventilation—Situate the unit so that it receives proper ventila- tion. Do not install in a confined space such as a bookcase or cabinet. Allow at least 10 cm (4 inches) clearance from the rear of the unit. To prevent the risk of electric shock or fire due to overheating ensure curtains and other materials do not obstruct the unit’s ventilation.

2.Foreign material—Ensure objects and liquids do not get into the unit. Avoid exposing the unit to excessive smoke, dust, me- chanical vibration, and shock.

3.Magnetism—Situate the unit away from equipment and devices that generate strong magnetic fields.

4.Stacking—Do not place heavy objects on top of this unit.

5.Surface—Place the unit on a flat, level surface.

6.Carts and stands—Use the unit only with carts and stands recommended by the manufacturer. Move carts with care. Sudden stops, excessive force, and uneven surfaces can cause carts to overturn.

7.Wall and ceiling mounting—Do not mount the unit on walls or ceilings unless specified in the instructions.

Environment

1.Water and moisture—Do not use the unit near water, such as near a bathtub or swimming pool. Avoid damp basements.

2.Heat—Situate the unit away from heat sources, such as radiators.

Do not situate where temperatures fall below 5oC (41oF) or rise above 35oC (95oF).

Item 2 in “Safety” applies only in the U.S.A. and Canada.

3.Power lines—Take care when setting up an outdoor antenna that it is not near overhead power lines, electric lights, or electri- cal circuits, and that there is no danger of the antenna falling on power lines, electric lights, or electrical circuits. When installing an outdoor antenna, take extreme care not to touch such power lines or circuits, as contact with them can be fatal.

4.Outdoor antenna grounding—If you connect an outdoor an- tenna, ground the antenna system to protect against voltage surges and built-up static charges. Section 810 of the National Electrical Code, ANSI/NFPA No. 70-1990, provides information about grounding of the mast and supporting structure, ground- ing of the lead-in wire to an antenna discharge unit, size of grounding conductors, location of antenna-discharge unit, con- nection to grounding electrodes, and requirements for the grounding electrode. Refer to this diagram.

 

 

ANTENNA

 

 

LEAD IN

 

GROUND

WIRE

 

 

 

CLAMP

 

ELECTRIC

 

ANTENNA

 

DISCHARGE UNIT

SERVICE

 

(NEC SECTION 810-20)

EQUIPMENT

 

 

 

 

GROUNDING CONDUCTORS

 

 

(NEC SECTION 810-21)

 

 

GROUND CLAMPS

 

 

POWER SERVICE GROUNDING

 

 

ELECTRODE SYSTEM

 

 

(NEC ART 250, PART H)

NEC—NATIONAL ELECTRICAL CODE

Maintenance

(See page 35 for details.)

Unplug the unit from the household AC outlet before cleaning. Clean with a damp cloth.

Do not use abrasive pads, scouring powders, or solvents.

Service

1.Damage requiring service—The unit should be serviced by qualified service personnel if:

(a)The AC power supply cord or the plug has been damaged; or

(b)Objects or liquids have gotten into the unit; or

(c)The unit has been exposed to rain; or

(d)The unit does not operate normally or exhibits a marked change in performance; or

(e)The unit has been dropped or the cabinet damaged.

2.Servicing—Do not attempt to service the unit beyond that de- scribed in these operating instructions. Refer all other servicing to authorized servicing personnel.

3.Replacement parts—When parts need replacing ensure the servicer uses parts specified by the manufacturer or parts that have the same characteristics as the original parts. Unautho- rized substitutes may result in fire, electric shock, or other hazards.

4.Safety check—After repairs or service, ask the servicer to per- form safety checks to confirm that the unit is in proper working condition.