Panasonic TC-P42X1, TC-P42S1, TC-P50S1, TC-P46S1, TC-P50X1 manual Power On Operation, Slide #28

Models: TC-P42X1 TC-P46S1 TC-P50S1 TC-P42S1 TC-P50X1

1 77
Download 77 pages 49.95 Kb
Page 28
Image 28
Power On Operation

Power On Operation

The power command from the power switch on the S board or the remote control receiver on the K board is provided to the Main CPU on the A board (IC1100) thru connector A1. The CPU on the A board outputs the “TV_SUB_ON” Command (3.2V) and the PANEL_STB_ON” command (3.2V).

The “TV_SUB_ON” command is provided to pin 6 of connector P7 of the power supply through pin 14 of connector A6 of the A board to develop the F_STB+15V. At this time the relays on the power supply are triggered and a “click” sound can be heard.

The F+15V from the P board is applied to several voltage regulator (IC5603, IC5401, and IC5607) on the A board.

The voltage outputs from these ICs are called SUB5V, SUB9V, SUB3.3V, SUB1.8V, SUB1.3V, and BT30V. They used by various circuits on the A board.

To avoid catastrophic failures, they are monitored by an SOS Detect circuit (IC5480) for over-voltage and over-current conditions. This SOS Detect circuit is controlled by the TV_SUB_ON command from the Main CPU (IC1100).

Any abnormalities of the SUB5V, SUB9V, or BT30V triggers the SOS circuit. The TV shuts down and the power LED blinks 10 times.

The “PANEL_STB_ON” is used to turn on the 3.3V regulator (IC9004) on the A board. The output voltage is applied to the “Panel” CPU on the A board (Formerly located in the D board).

The Panel CPU on the A board outputs the “PANEL_MAIN_ON” Command (3.2V) to pin 11 of connector P25 on the P board.

The PANEL MAIN ON command turns on the power supply circuit that outputs the Vsus, Vda, 15V, and 5V.

Slide #28

Page 28
Image 28
Panasonic TC-P42X1, TC-P42S1, TC-P50S1, TC-P46S1, TC-P50X1 manual Power On Operation, Slide #28