Options Adjustments

Item

 

 

 

 

Adjustments

 

Off

PC

INPUT1

INPUT2

INPUT3

 

Locks the input switch operation.

 

 

Notes:

 

 

 

 

 

• Only the adjusted signal is displayed (see page 15).

INPUT lock

• Signal can be displayed when the Terminal board is installed.

• Input switch can be used when this is set to “Off”.

 

In two screen display mode, if anything other than “Off” is set, the value will be fixed as the value input in the single screen display mode.

When a dual input terminal board is attached, A or B is displayed depending on the selected input signal. (Ex. INPUT1A, INPUT1B)

 

Off

 

MENU&ENTER

On

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Off: All the buttons on main unit can be used.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MENU&ENTER:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Locks

MENU and

ENTER/ buttons on right side of main unit.

 

 

 

Button lock

On: Locks all the button on bottom face of main unit.

 

 

 

 

 

 

 

 

 

 

Sets Button lock with the unit buttons in the following procedure.

 

 

 

 

 

 

 

 

 

Off: Press

+ /

four times→Press

 

INPUT four times→Press

- /

 

 

 

four times→Press

ENTER/

 

MENU&ENTER: Press

ENTER/

four times→Press

 

 

+ / four times→Press

INPUT four times→Press

ENTER/

 

On: Press

- /

four times→Press

 

ENTER/ four times→Press

+ /

four times→Press

 

ENTER/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Off

 

User1

 

User2

 

 

User3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Off:

 

You can use all of the buttons on the remote control.

 

 

 

 

 

 

 

 

 

Remocon User level

User1:You can only use

,

, ,

 

 

 

 

 

 

, ,

,

,

 

 

 

 

buttons on the remote control.

 

 

 

 

 

 

User2:You can only use

,

, buttons on the remote control.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User3:Locks all the buttons on remote control.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Enable: Enables the “Off-timer function”.

 

 

 

 

 

 

 

 

 

 

 

 

 

Off-timer function

Disable: Disables the “Off-timer function”.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: When “Disable” is set, the Off-timer is cancelled.

 

 

 

 

 

 

 

 

 

 

Normal

Standby

 

On

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sets the power mode of the unit for when the power recovers from failure or after plugging off and in again.

Initial Power Mode

Normal: Power returns in as the same state as before the power interruption.

 

 

Standby: Power returns in standby mode. (Power Indicator : red/orange)

 

 

 

 

 

 

On:

 

Power returns in power On. (Power Indicator : green)

 

 

 

 

 

 

 

 

 

Note: When using multiple displays, “Standby” is preferred to be set in order to reduce a power load.

 

Sets panel ID number when panel is used in “Remote ID” or “Serial ID”.

 

 

ID select

Set value range: 0 - 100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Standard value: 0)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The setting of this menu is valid only when using ID remote control.

 

 

 

 

Off:

 

Disables ID remote control functions. You can use normal remote control operations.

 

Remote ID

On:

 

Enable ID remote control functions.

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: To use the ID remote control function, it is necessary to set each ID number of remote control and

 

 

 

display unit. About the setting method, please refer to “ID Remote Control Function” (see page 46)

 

 

and “ID select” (above-mentioned).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sets the panel ID Control.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Serial ID

Off:

 

Disables external control by the ID.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

On:

 

Enables the external control by the ID.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Adjusts the image display size on screen.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Off:

 

Sets the normal image display size on screen.

 

 

 

 

 

 

 

 

 

 

On:

 

Sets the image display size approximately 95 % of the normal image display.

 

 

 

 

 

 

Off

 

 

 

 

 

 

On

 

 

 

 

 

 

 

 

 

 

 

 

 

Display size

Notes:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• This setting is valid only when the input signals are as follows;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NTSC, PAL, SECAM, M.NTSC, PAL60, PAL-M, PAL-N (BNC Dual Video Terminal Board (TY-FB9BD))

 

525i, 525p, 625i, 625p, 750/60p, 750/50p, 1125/60i, 1125/50i, 1125/24sF, 1125/25p, 1125/24p, 1125/30p,

 

1125/60p, 1125/50p, 1250/50i (Component Video, RGB, DVI, SDI, HDMI)

 

 

 

• This setting is invalid when two screen display, digital zoom, Multi display or Portrait display is selected.

 

• When “Display size” is set to “On”, “H-POS” and “V-POS” in “POS. /SIZE” can be adjusted.

 

 

• Refer to each board’s operating instruction for DVI, SDI, HDMI’s corresponding signals.

 

 

56

Page 56
Image 56
Panasonic TH-85PF12U operating instructions Options Adjustments, Button lock