Journals and Lists

Power Failure Report

The UF-770 has a built-in rechargeable battery installed to retain the document information for up to 1 hour when a power failure occurs.

However, if the battery system has problems, the document information might be lost. In this case, a Power Failure Report will be printed automatically for each file separately, after the Power is turned ON again. This report is not printed if there were no files in the memory.

Sample Power Failure Report

*************** -POWER FAILURE REPORT- ***************** DATE 08±MAR-1997 ***** TIME 15:00 *** P.01

POWER FAILURE OCCURRED !

FROM *** 08±MAR-1997 10:00 *** (1)

TO *** 08±MAR-1997 15:00 *** (2)

FOLLOWING FILE(S) HAS BEEN LOST.

(3)

(4)

(5)

(6)

 

(7)

 

FILE NO.

COMM.TYPE

ABBR NO.

STATION NAME/TEL NO.

PAGES

 

002

MEM.POLLED XMT

 

 

 

003

 

003

RCV TO MEMORY

 

 

 

005

 

015

MEM.DEF.XMT

<01>

SALES DEPT.

000/003

 

 

 

<02>

SERVICE DEPT

000/003

 

018

MEMORY XMT

<03>

ACCOUNTING DEPT.

005/005

 

 

 



021 111 1234

000/005

 

 

 

 

 

-PANASONIC

 

-

************************************ -HEAD OFFICE

- ***** -

201 555

1212- *********

Explanation of Contents

(1)Power failure date and time

(2)Power return date and time

(3)File number

(4)Communication type

(5)Abbreviated number or  mark

(6)Recorded name in One-touch, ABBR. or Manual Number dialling

(7)Number of pages stored

:001 to 255. (When the communication for each communication)

: mark indicates dialed by Manual Number dialling

:The first 3-digit number represents the number of page successfully transmitted. The second 3-digit number represents the number of pages stored in memory.

152