54
Configure the alarm settings [Alarm]
The settings relating to alarm occurrences such as settings for the alarm action at an alarm occurrence, the VMD
area settings, and the alarm occurrence notification can be configured on this page.
The "Alarm" page has 3 tabs; the [Alarm] tab, the [VMD area] tab and the [Notification] tab.

Configure the settings relating to the alarm action [Alarm]

Click the [Alarm] tab on the "Alarm" page. (pages 20 and 21: How to display/operate the setup menu)
The settings relating to the alarm can be configured in this section. Refer to pages 55 and 57 for further information
about the settings relating to the alarm and the alarm output terminal.

Alarm

[Terminal 1]
Determine how to use terminal 1.
Alarm input: Receives alarms.
Black & white input:Receives the black & white
switchover input. (When the input is set to On, the
black & white mode is activated.)
Off: Not used.
Default: Off
[Terminal 2]
Determine how to use terminal 2.
Alarm input: Receives alarms.
Alarm output: Alarm output will be carried out accord-
ing to the settings for "Alarm output terminal setup"
(page 57).
Off: Not used.
Default: Off
[Terminal 3]
Determine how to use terminal 3.
Alarm input: Receives alarms.
AUX output: AUX output will be supplied. The [AUX]
buttons will be displayed on the "Live" page.
Exposure output: The CCD exposure timing pulse
output is provided. (The close output is provided
only during CCD exposure.)
Off: Not used.
Default: Off
Note:
AUX is a camera terminal that allows users to oper-
ate (Open/Close) arbitrarily from the "Live" page. For
example, an operator can remotely control lights in a
place where the camera is installed by connecting
the terminal to the light controller.
Refer to the installation guide for further information
about input/output terminals.
[VMD alarm]
When clicking "VMD >>", the [VMD area] tab of the
"Alarm" page will be displayed.
[Command alarm]
Select "On" or "Off" to determine whether or not to
receive the command alarm.
The command alarm is the function that provides notifi-
cation of a Panasonic protocol alarm from the other
cameras. When "On" is selected, alarm actions will be
performed between multiple cameras.
Default: Off
[Originating port number]
Select a port number to be used to receive the com-
mand alarm.
Available range: 1 - 65 535
Default: 8 181