RCP2-1000 RM Remote Controller Operations Manual 203987 Rev A 21
3.2.1.2 Sys Info Page 2
This page shows a variety of alarm states which may be present within the HPA. Fault
values could be "Fault", "Normal" and "N/A"
PS - power supply alarm, displays "Normal" if HPA power supplies are normally op-
erational and "Fault" if one or more power supplies failed.
LowRF - low RF fault;
Fan - cooling system failures;
Aux. - Auxiliary fault condition;
VSWR - High Reflected power fault;
BUC - Block Up converter fault.
If the fault condition doesn't apply to the HPA configuration it will display "N/A" for "Not
Available".
3.2.1.3 Sys Info Page 3
This page displays miscellaneous information related to the redundancy operation and
the HPA mute status.
RFSW1 - state of RF switch 1, possible values - "Pos1" Pos2" "N/A", "Fault";
RFSW2 - state of RF switch 2, possible values - "Pos1" Pos2" "N/A", "Fault";
State - HPA online state, possible values "Online", "Standby";
Mute - HPA mute state, possible values "Clear", "Set";
Prior - Priority polarization select (1:2 Mode Only);
PolSel - Current Polarization output (1:2 Mode Only)
3.2.1.4 Sys Info Page 4
This page displays various HPA settings:
Prtcl. - current HPA remote control protocol. The value can be set to "Terminal", if
terminal mode protocol is currently active and "Normal" for string I/O type protocol.
Baud - selected baud rate for remote control serial port. Selection: "2400", "4800",
"9600", "19200", "38400";
Intrfc. - selected serial port interface. Selection: "RS232", "RS485".
Addrs. - HPA remote control network address. Value could be in range from 0 to
254. Note: address 255 is reserved for global calls and shouldn't be used for indi-
vidual units addressing.
Buzzer - Audible alarm availability. "Dis" if alarm disabled and "Enb" if enabled.
Latch - Fault latch option selection. "Dis," indicates disabled option and "Enb" - en-
abled.