RCP2-1000 RM Remote Controller Operations Manual 203987 Rev A 9
1.3.2 Electrical Discharge Hazards
A spark can not only create ESD reliability problems, it can also cause serious safety
hazards. The following precautions should be taken when there is a risk of electrical
discharge:
Follow all ESD guidelines.
Remove all flammable material and solvents from the area.
All probes and tools that contact the equipment should be properly insulated
to prevent electrical discharge.
The work area should be secure and clear from non-essential items.
Operators should never work alone on high voltage devices. There should
always be another person present in the same work area to assist in the
event of an emergency.
Operators should be familiar with procedures to employ in the event of an
emergency, i.e. remove all power, CPR, etc.
1.4 Specification Summary
Table 1-1 contains a summary of the specifications of the RCP2-1000 RM redundant
system controller.
Configurations RCP2-1000 RM; 1:1 Redundant System
Switch Time Fault Detection, 20-50 msec
Total switchover, 100 msec maximum
Switch Drive 26 VDC @ 4 amps
Alarm Input Closure to Ground, (Ground = OK / Open = Fault)
Parallel I/O
Status Outputs
Control Inputs
Form C Relay Contacts (10 sets)
Contact Closure to Ground
Table 1-1: RCP2-1000 RM Specification Summary
AC Input Power 85-265 VAC, 47-63 Hz, 1 A max, > 0.93 power factor
Mechanical Dimensions 1.75 in. H x 19 in. W x 13.3 in. D [1 RU]
(89 mm H x 483 mm W x 338 mm D)
Weight 5 lb (2.3 kg)
Environmental Temperature 0 - 50 oC