DSU Operations
5-373610-A2-GB41-60 March 1999
Port Option Sets
The Prt1 through Prt6 selections allow configuration
options to be set on a per-port basis for TDM, MCMP, or
Bridge mode.
In TDM or MCMP mode, the Prt1 through Prt6
selections are available. In Bridge mode, the Prt2 through
Prt6 selections are available; selections for Prt1 are set
via the DSU and Gen submenus (option sets).
F1
Change MUX Opts:
Copy Setup Prt1
F2 F3
Prt3 Prt4 Prt5 Prt6Prt2
In a port path, you are presented with the configuration
options listed in Table 5-10. In this table, the
configuration options with an X for a particular mode are
valid for the mode selected. A configuration option
without an X either does not appear in that mode, is forced
to a certain value, or has no meaning for that mode. For an
option forced to a certain value, all of the values normally
available to that option still appear, but changes made
have no effect; the configuration option’s value is not
overwritten in software.
The Copy selection allows the set of configuration
options that have been specified for a port to be copied
into another port, or into all other ports. There are two
menus associated with Copy: Copy from and Copy to.
To access the Copy from menu,
F1
Change MUX Opts:
Copy Setup Prt1
F2 F3
Prt3 Prt4 Prt5 Prt6Prt2
F1
Copy from:
Prt1 Prt2 Prt3
F2 F3
Prt3 Prt4 Prt5 Prt6Prt2
The Prt1 selection in the Copy from menu appears in
TDM or MCMP mode (shown above), but not in Bridge
mode. Select a port (for this example, Port 3 is selected).
The Copy to menu appears.
F1
Copy Prt3 to:
All Prt1 Prt2
F2 F3
Prt3 Prt4 Prt5 Prt6Prt2
If All is selected, a set of Prt3 configuration option
values will be written to each port: Prt1 through Prt6 in
TDM or MCMP mode, and Prt2 through Prt6 in Bridge
mode. If a port is selected, the Prt3 configuration option