COMSPHERE 392xPlus Modems
4-2 November 1996 3920-A2-GN31-30
•Factory is a read-only (unchangeable) configuration area containing six sets of predefined
configuration options labeled
Sync Leased
,
Async Leased
, TMp (Trellis Multipoint),
Async Dial
, Sync Dial
, and
UNIX Dial
. If Sync Leased or Async Leased is selected, you
must choose either
Answer or Originate
mode. If TMp is selected, you must choose either
Control or Trib (T
ributary) mode. These sets contain the most commonly used
configurations options for modems installed into these hardware environments. These
predefined configuration options are intended to give you a head start and only require a
minimum of changes to the default settings. Factory default settings are listed in
Appendix F.
Figure 4-1 graphically displays the interaction between the edit area and configuration areas as
viewed from the perspective of the DCP.
CONTENTS O
F
Activ
e (
Saved)
A
RE AUTOMATICALLY COPIED
TO Activ
e (
Operating)
W
HEN A SAV
E I
S COMMANDED VI
A T
HE
DCP, ON A RESET, OR ON POWER-UP.
Active (Operating)
Active (Saved)
Customer1 Customer2 Factory
EDIT AREA
ALLOWS YOU TO VIEW AND
EDIT CONFIGURATION OPTIONS
ANY CHANGE
S M
AD
E T
O
CONFIGURATION OPTIONS
ARE SAVED TO Activ
e (
Saved),
Customer1
,
OR Customer2
Loa
d E
dit
Are
a F
rom
SSync
Leased*
(Answer/Originate)
S
Async Leased*
(Answer/Originate)
S
TMp (Control/T
rib)
S
Async Dial
S
Sync Dial*
S
UNIX Dial
Save
To
*Multiport mode
Figure 4-1. DCP Configuration Process