Cables You May Need to Order

You will need cables to connect your Network Interface Module (NIM) to the network and your 7511 DSUs to DTEs. For further information refer to the documentation shipped with your NIM, and Appendix A, Cables and Pin Assignments, in the User's Guide.

Installing the Dual DSU

Before you install your DSU, read the Important Safety Instructions beginning on page 13.

!HANDLING PRECAUTIONS FOR STATIC-SENSITIVE DEVICES

 

The Model 7511 Dual DSU is designed to protect sensitive components

 

from damage due to electrostatic discharge (ESD) during normal

 

operation. When performing installation procedures, however, take

 

proper static control precautions to prevent damage to equipment. If

496-15104

you are not sure of the proper static control precautions, contact your

nearest sales or service representative.

 

Configuring the DSUs

"Procedure

To configure the Model 7511 Dual DSU:

1.Review Table 1 to determine the proper settings for your environment.

The first choice for each option (shown in boldface type) is the factory default setting. If you choose the factory default value, you do not need to change the position of the associated switch.

2.Mark any options in the table that you wish to differ from the factory default.

3.Using Figure 1 and Table 1, verify that the switch settings of each DSU on the 7511 card match your selections.

Do not modify the settings of switches not listed in the table. Any switch not designated for customer use should be in the Off position.

4.Where required, verify that the local and remote DSUs employ the same options. For example, both the local and remote DSU must use the same Line Rate and 64CC Data Scrambler settings.

2

January 1999

7511-A2-GN10-10