Maintenance
4-13
3160-A2-GB21-80 March 1999
Table 4-4. Enterprise-Specific Trap Definitions
Trap Value Event
enterpriseClockFail(1) The currently configured master clock source has failed.
enterpriseSelfTestFail(2) A DSU/CSU hardware failure is detected at self-test. This
trap is generated after DSU/CSU initialization.
enterpriseDeviceFail(3) An internal DSU/CSU failure is detected by the operating
software.
enterpriseTestStart(5) A test is initiated.
enterpriseConfigChange(6) A configuration option is changed.
enterpriseTestClear(105) A test is concluded.
Table 4-5. SNMP Trap per Interface
Interface Trap Meaning
T1 Network Up = No alarm or test conditions.
Down = Alarm or test conditions.
DTE Drop/Insert (DSX-1) Up = No alarm or test conditions, and the interface is
enabled.
Down = Alarm or test conditions, or the interface is
disabled.
Synchronous Data Ports Up = No test conditions, the port is assigned to a network
interface, and both CTS and DSR are ON.
Down = Test conditions, the port is unassigned, or either
CTS or DSR is off.