Operating Your Cleaner

If this is the first time you are using the cleaner, please read this whole section before proceeding.

Before You Start Cleaning

CAUTION

Do not place parts or containers directly on the bottom of the cleaning tanks; use a basket, wire hook or other device to suspend items.

Do not allow the cleaning solution level to drop more than one inch below the top of the tank with the cleaner on.

Do not ever use alcohol, gasoline or flammable solutions. Doing so could cause a fire or explosion. Use only water-based solutions.

Do not ever use mineral acids. These could damage the tank. Failure to comply with these cautions will void your warranty.

Operating Your PC-620-1 or PC-620-2 Cleaner

Explanation of Controls

Control

Function

ULTRASONIC

Activates and de-activates ultrasonic cavitation in the

POWER SWITCH

tank

 

 

 

HEATER SWITCH

Activates the external heater on the cleaning tank. The

 

heater power has been selected to provide the

 

optimum temperature for most cleaning applications.

7Operating Your Cleaner

Page 11
Image 11
Paragon PC-620-2, PC-620-1 manual Operating Your Cleaner, Before You Start Cleaning