Parker Hannifin N dimensions Solenoid Valves External Supply

Models: N

1 26
Download 26 pages 25.03 Kb
Page 8
Image 8

Catalog 0600P-10/USA

“N” Series Valves

Technical Information

Pilot Supply

 

 

Operating Pressure

Internal Pilot – Solenoid Valves

3/8" & 3/4" Body

• 20 to 140 PSIG (standard)

1-1/4" Body

• 25 to 140 PSIG (200 PSIG option available)

Internal Pilot – Remote Pilot Valve

Operating Pressure Limitations

Air Pressure

Remote Pilot Pressure (PSI)

Thru Valve

3/8" Basic 

3/4" Basic

1-1/4" Basic

  25 PSI

30-250

30-250

30-250

50 PSI

50-250

50-250

50-250

75 PSI

70-250

75-250

70-250

100 PSI

95-250

95-250

90-250

150 PSI

140-250

145-250

130-250

200 PSI

175-250

185-250

175-250

250 PSI

215-250

230-250

205-250

Solenoid Valves: External Supply

3/8" & 3/4" Basic

Air Pressure

External Pilot Pressure Required (PSI)* 

Thru Valve (PSI)

3/8" Basic

3/4" Basic

25 PSI

35-200

35-200

50 PSI

45-200

40-200

75 PSI

55-200

50-200

100 PSI

65-200

65-200

150 PSI

80-200

80-200

250 PSI

110-200

110-200

Vacuum up to 1" HG, less than a perfect vacuum. * With 200 PSI option.

Do not exceed 140 PSI with standard pilots.

M

3/8" & 3/4" Body

Single Solenoid External Pilot

Normally Closed

3/8" & 3/4" Body

Single Solenoid External Pilot

Normally Open

3/8" & 3/4" Body

1-1/4" Body

Remote Operated External Return

Normally Closed

3/8" & 3/4" Body

1-1/4" Body

Remote Operated External Return

Normally Open

External Pilot supply should be used when the main valve needs to operate below the Minimum Operating Pressure or at Vacuum. A Selector function can also be achieved (pressurizing the IN and EXHAUST ports) with an External Pilot Supply. Refer to charts for required external pilot pressure.

M8Parker Hannifin Corporation

Pneumatic Division

Richland, Michigan

www.parker.com/pneumatics

Page 8
Image 8
Parker Hannifin N dimensions Solenoid Valves External Supply