Parker Hannifin VO40 manual Main Relief Options, 17C - Relief Flow Setting

Models: VO40

1 28
Download 28 pages 50.54 Kb
Page 17
Image 17
[16] - Main Relief Options

Catalog HY17-8505/UK

Open-Center Directional Control Valve

Ordering Information – Inlet Cover

VO40

 

 

[16] - Main Relief Options

 

PS Adjustable main pilot-operated relief.

Adjustment range: 50 to 300 bar (725 to 4300 PSI).

PB Adjustable main pilot-operated relief (Tamperproof aluminum cap).

Adjustment range: 50 to 300 bar (725 to 4300 PSI).

PN Adjustable main direct-acting relief.

Adjustment range: 60 to 207 bar (900 to 3000 PSI).

PA Adjustable main direct-acting relief (Tamperproof aluminum cap).

Adjustment range: 60 to 207 bar (900 to 3000 PSI).

YY plug (cavity machined and plugged).

[17]– Pressure Setting – Enter pressure setting (PSI or Bar)

Note: Relief valve code PN and PA max setting is 207 bar (3000 PSI).

[17C] – Relief Flow Setting

Flow in LPM or GPM.

13

Parker Hannifin Corporation

Page 17
Image 17
Parker Hannifin VO40 manual Main Relief Options, 17C - Relief Flow Setting, Open-Center Directional Control Valve