3.2 SETTING THE DCE/DTE SWITCH
Correct setting of the DCE/DTE switch eliminates the need for RS- 232 crossover cables. If the
3.3 SETTING THE CARRIER CONTROL STRAP (see Note 2)
The setting of the carrier control strap determines whether carrier is “constantly on” or “controlled by RTS”. For “controlled by RTS” position the strap on pegs 1 & 2. For “constantly on” position the strap on pegs 2 & 3. Figure 2 (below) shows the two possible settings of the carrier control strap.
1 | 2 | 3 | 1 | 2 | 3 | 1 | 2 | 3 |
Figure 2 Model 1050 strap settings
NOTE 1: If you are connecting twisted pair to the Model 1050 using the internal terminal blocks, make the twisted pair connection before
NOTE 2: If you are using the Model 1050 in a multipoint application, consult Section 4.2 for proper Master and Slave carrier control settings.
5
4.0 INSTALLATION
The Model 1050 is easy to install. After configuring the unit properly, you will need to connect the two twisted pairs and the
Made In The USA
Powered Async. Short
Range Modem
Power | Line |
Figure 3. Rear view of 1050 showing interface connectors
4.1 TWISTED PAIR WIRING OVERVIEW
These short range modems are designed to work in pairs. You will need one at each end of a
XMT + |
| RCV+ | }One Pair |
XMT - |
| RCV - | |
G | To Shield (Optional) | G |
|
RCV - |
| XMT - |
|
RCV + |
| XMT + }One Pair |
4.1.1 TWISTED PAIR CONNECTION USING TERMINAL BLOCKS
The Model 1050 terminal block is located on the PC board inside the unit. To access the PC board, remove the two screws on the back panel and slide the PC board out of the case. Connect the bare twisted pair wires by first inserting them through the grommet on the back panel, then stripping the ends and connecting the individual leads to the terminal block. Be sure the
6