Patton electronic 2073 Configuring The Hardware Dip Switches, Configuration DIP Switch Set “S1”

Models: 2073

1 13
Download 13 pages 41.42 Kb
Page 4
Image 4
3.1 CONFIGURING THE HARDWARE DIP SWITCHES

3.0 CONFIGURATION

The Model 2073 is equipped with two sets of eight DIP switches, which allow configuration of the unit for a wide variety of applications. This section describes switch locations and explains all possible con- figurations.

3.1 CONFIGURING THE HARDWARE DIP SWITCHES

The 16 external switches are grouped into two eight-switch sets, and are externally accessible from the underside of the Model 2073.

Front

Rear

Figure 1. Underside of Model 2073, Showing Location of DIP Switches

The two sets of DIP switches on the underside of the Model 2073 will be referred to as S1 and S2. As Figure 2 shows, the orientation of all DIP switches is the same with respect to “ON” and “OFF” positions.

ON

OFF

Figure 2. Close Up of Configuration Switches (all sets are identical in appearance)

3.1.1 Configuration DIP Switch Set “S1”

S1 Summary Table

Position

Function

 

 

 

Factory Default

S1-1

DTE Data Rate

On

 

 

 

 

 

 

 

 

}

 

 

 

 

S1-2

DTE Data Rate

On

 

 

 

 

 

 

 

64kbps

 

 

S1-3

DTE Data Rate

On

 

 

 

 

 

 

 

 

 

S1-4

DTE Data Rate

On

 

 

 

 

 

S1-5

Transmit Clock Source

On

}

 

 

 

 

 

 

 

 

Network (Normal)

 

S1-6

Transmit Clock Source

Off

S1-7

Reserved

Off

 

 

 

 

 

 

 

S1-8

V.54 Prep Phase Reception

On

 

 

 

 

Enabled

Switches S1-1 thru S1-4: DTE Data Rates

The DTE synchronous and asynchronous data are determined by the combined switch settings of S1-1,S1-2,S1-3, and S1-4. The follow- ing table lists all the possible switch combinations and the correspon- ding DTE data rates:

 

 

 

 

 

 

 

 

Data Rate

S1-1

S1-2

S1-3

S1-4

 

 

9600

Off

On

On

Off

 

 

14.4

Off

On

On

On

 

 

19.2

On

Off

Off

Off

 

 

28.8

On

Off

Off

On

 

 

32

On

Off

On

Off

 

 

38.4

On

Off

On

On

 

 

48

On

On

Off

Off

 

 

56

On

On

Off

On

 

 

57.6

On

On

On

Off

 

 

64

On

On

On

On

 

 

 

 

 

 

 

 

NOTE1: The four data rate configuraton switches are ignored when Octet Timing Mode is selected (S2-1 is set to the “On” position, D8=1). In Octet Timing Mode, the data rate defaults to 128kbps.

NOTE2: Asynchronous rates are 9600, 14,400, and 19,200. To run in asynchro- nous mode, set the 2073 for 64K synchronous to over sample the data bits.

5

6

Page 4
Image 4
Patton electronic 2073 Configuring The Hardware Dip Switches, Configuration DIP Switch Set “S1”, Front Rear, On Off