Patton electronic 2703-X21 External Dip Switch Settings, Switch Set S1, S1 SUMMARY TABLE

Models: 2703-X21

1 10
Download 10 pages 44.16 Kb
Page 3
Image 3
3.1 EXTERNAL DIP SWITCH SETTINGS

3.0 CONFIGURATION

The Model 2703-X21 is equipped with one DIP set containing eight switches (externally accessible), as well as seven jumpers (internal). These switches and jumpers allow configuration of clocking, data rate, and test options. The Model 2703-X21 is also equipped with an internal switch that allows selection of 115 or 230 VAC power inputs (Note: this switch is not present in Models 2703-X21-UI and 2703-X21-DC). This section describes switch and jumper locations and explains all possible configurations.

3.1 EXTERNAL DIP SWITCH SETTINGS

The Model 2703-X21’s DIP switch set is located on the underside of the unit (see Figure 1, below). Figure 2 (below), shows the orientation of the switch set. All possible settings for the Model 2703- X21’s switches are presented in the summary table and descriptions on the following pages. If you have additional questions regarding configuration, contact Patton Technical Support at (301) 975-1000.

S1

Figure 1. Underside of Model 2703, showing external DIP switch location

Switch Set S1

The configuration switches on S1 set clocking, rate adaptation, loopback enable, and data invert. The default settings are summarized in the table below.

S1 SUMMARY TABLE

Position

Function

Factory Default

 

 

 

 

 

S1-1

Clock Master/Slave

On

 

Master

 

 

 

 

 

S1-2

Rate Adaptation

Off

}

2.048 Mbps

S1-3

Rate Adaptation

Off

 

 

 

 

 

S1-4

Test Enable

Off

 

Front Panel

 

 

 

 

 

S1-5

Data Inversion

Off

 

Not Inverted

 

 

 

 

 

S1-6

Not Used

Off

 

N/A

 

 

 

 

 

S1-7

Not Used

Off

 

N/A

 

 

 

 

 

S1-8

Not Used

Off

 

N/A

 

 

 

 

 

S1-1: Master/Slave Clock

The setting for switch S1-1 determines whether the Model 2703-

X21 provides the master clock, or is slaved to another clock source.

S1-1

Setting

On

Model 2703-X21 is master

Off

Model 2703-X21 is slave, (clock is recovered

 

from the network)

O N

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DHS-8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 2. Close up of configuration switches

3

4

Page 3
Image 3
Patton electronic 2703-X21 External Dip Switch Settings, Switch Set S1, S1 SUMMARY TABLE, S1-1 Master/Slave Clock