Patton electronic 2703-X21 Jumper Summary Table, LK1 75 Ohm Transmit Shield-to-Ground Connection

Models: 2703-X21

1 10
Download 10 pages 44.16 Kb
Page 5
Image 5
JUMPER SUMMARY TABLE

LK2

LK6

LK7

LK5

LK3

LK4

LK1

Figure 5. Jumper locations on Model 2703 PC board.

The table below shows the factory default jumper settings. Following the table are descriptions for each jumper.

JUMPER SUMMARY TABLE

Jumper

Function

75 ohm

120 ohm

Factory Default

 

 

 

 

 

LK1

75 Ohm TX Shield to GND

On

Off

On (connect)

 

 

 

 

 

LK2

75 Ohm RX Shield to GND

Opt.*

Off

Off (disconnect)

 

 

 

 

 

LK3

Reserved

 

 

Off

 

 

 

 

 

LK4

120 Ohm Shield to GND

Off

Opt.

Off (disconnect)

 

 

 

 

 

LK5

Configuration Auto-Sense

On

Opt.

On (enabled)

 

 

 

 

 

LK6

75 Ohm Input Impedance

On

Off

} On (75 Ohm)

LK7

75 Ohm Input Impedance

On

Off

 

 

 

 

 

*Opt. = optional setting, all others are required for proper operation

NOTE: one combination of jumper settings is required for 75 ohm operation, and another combination is required for 120 ohm operation. The Model 2703 is factory configured for 75 ohm operation.)

LK1: 75 Ohm Transmit Shield-to-Ground Connection

This setting determines whether the shield of the 75 Ohm (coax) transmit cable is connected to earth ground. This connection must be made when operating in 75 Ohm (unbalanced) mode. Conversely, this connection must not be made when operating in 120 Ohm (balanced) mode.

LK1

Setting

Strap On

75

Ohm TX Shield-to-GND Connection Made

Strap Off

75

Ohm TX Shield-to-GND Connection Broken

LK2: 75 Ohm Receive Shield-to-Ground Connection

This setting determines whether the shield of the 75 Ohm (coax) receive cable is connected to earth ground. This connection is optional when operating in 75 Ohm (unbalanced) mode. This connection must not be made when operating in 120 Ohm (balanced) mode.

LK2

Setting

Strap On

75

Ohm RX Shield-to-GND Connection Made

Strap Off

75

Ohm RX Shield-to-GND Connection Broken

LK3: DIP Switch S1-1 Enable

This strap is reserved for future use and must remain Off.

LK3

Setting

Strap On

Not a Valid Setting

Strap Off

Normal Setting

LK4: 120 Ohm Shield-to-Ground Connection

This setting determines whether the shield of the 120 Ohm (modular) cable is connected to earth ground. This connection is optional when operating in 120 Ohm (balanced) mode. This connection must not be made when operating in 75 Ohm (unbalanced) mode.

LK4

Setting

Strap On

75

Ohm RX Shield-to-GND Connection Made

Strap Off

75

Ohm RX Shield-to-GND Connection Broken

7

8

Page 5
Image 5
Patton electronic 2703-X21 user manual Jumper Summary Table, LK1 75 Ohm Transmit Shield-to-Ground Connection