Patton electronic Network Hardware, 275, 2715 BIT Error Rate V.52 Diagnostics, 511, 2047, Qrss

Models: Network Hardware 275 2715

1 21
Download 21 pages 15.85 Kb
Page 17
Image 17

To perform an RDL test, follow these steps:

1.Activate RDL. This may be done in two ways:

a.Enter b Remote Loop from the System Diagnostics/Statistics menu and toggle the <Spacebar> until “TM” appears next to the b Remote Loop option.;

b.Activate the “RL” signal on the DTE. If you are not sure which lead is the “RL” signal, please refer to Appendix D.

2.Perform a bit error rate test (BERT) using the internal V.52 generator (as described in Section 5.3), or using a separate BER Tester. If the BER test indicates a fault, and the Local Line Loopback test was successful for both NetLink™s, you may have a problem with the twisted pair line connection.

5.3 BIT ERROR RATE (V.52) DIAGNOSTICS

The Model 2715 offers three V.52 Bit Error Rate (BER) test pat- terns. These test patterns may be invoked along with the LAL and RDL tests to evaluate the unit(s) and the communication links.

When a 511, 2047, or QRSS test is invoked, the Model 2715 gen- erates a pseudo-random bit pattern of 511 bits, 2047 bits or 220 bits, respectively, using a mathematical polynomial. The receiving NetLink- E1™ then decodes the received bits using the same polynomial. If the received bits match the agreed upon pseudo-random pattern, then the Model 2715(s) and the communication link(s) are functioning properly.

511

Initiates a built-in 511 bit pseudo-random

 

pattern generator and detector.

2047

Initiates a built-in 2047 bit pseudo-random

 

pattern generator and detector.

QRSS

Initiates a built-in 220 bit pseudo-random

 

pattern generator and detector.

To perform a V.52 test, follow these steps:

1.Activate the local loopback or remote loopback diagnostic.

2.Activate the test pattern. This may be done in one of two ways:

a. Enter e Selected Pattern from the System Diagnostics/Statistics menu and toggle the <Spacebar> until the desired test pattern appears.

b.Enter c Test Pattern and toggle the <Spacebar> to send the selected pattern.

c.One of two result codes will appear to the right of the c Test Pattern listing:

OK Indicates that the received test pattern is error-free.

BE Indicates that there are errors in the test pattern (to deliberately insert errors in the pattern, toggle

dError Insertion to ON).

31

32

Page 17
Image 17
Patton electronic Network Hardware, 275, 2715 BIT Error Rate V.52 Diagnostics, 511, 2047, Qrss, Error Insertion to on